Description
The YG1817 Infant Radiant Warmer combines precision temperature control with intuitive operation for optimal neonatal thermoregulation. Featuring dual microcomputer-controlled modes (skin temperature sensor ±0.3°C accuracy and manual override), this medical-grade unit ensures rapid stabilization with ≤30 minute heat-up from 25°C to 37°C. The 770VA energy-efficient design includes tilting radiant canopy, four self-diagnostic alarm systems, and RS-232 connectivity for seamless integration with hospital monitoring networks.
Key clinical advantages:
- Real-time temperature monitoring with separate display windows
- APGAR timer (1/5/10 minute intervals) for standardized assessments
- Expandable functionality with optional phototherapy and oxygen modules
- Overheat protection with dual-stage alarms (<38°C/<39°C)
- Procedure lighting for improved visibility during interventions
Priced competitively in the mid-range medical equipment market, the YG1817 delivers exceptional value for delivery rooms, NICUs, and pediatric units requiring reliable newborn thermal support.
Frequently Asked Questions
- How does the skin temperature mode maintain stability? The medical-grade probe continuously adjusts heat output to maintain within ±0.3°C of setpoint, with auto-alerts for any deviations.
- Can this connect to our hospital’s EMR system? Yes, the RS-232 port enables data export to most electronic medical record systems with proper interface configuration.
- What’s included in the standard package? The base unit includes warmer, mattress, skin sensor, and procedure light – phototherapy/O₂ modules are optional upgrades.
Advantages and Disadvantages
Advantages
- Clinical Precision – Hospital-grade ±0.3°C accuracy meets JCI standards
- Future-Ready Design – Optional module expansion for evolving needs
- Safety Focused – Four self-check alarms prevent thermal risks
Disadvantages
- Basic Configuration – Critical accessories sold separately
- Power Demands – Requires stable 220V supply
- Training Needed – Multiple operation modes require staff orientation
Product Use in the Field
The YG1817 excels in:
- Hospital delivery rooms for immediate newborn care
- Neonatal transitional care units
- Pediatric emergency departments
- Maternal-child health clinics
Its rapid heating capability makes it particularly valuable for preterm infants and low birth weight babies requiring immediate thermal support.
Recommendations
For optimal clinical performance:
- Conduct weekly alarm tests to ensure proper function
- Rotate multiple skin probes to extend sensor life
- Document temperature logs for quality assurance
- Consider LED phototherapy option for jaundice cases
- Train staff on all operation modes and alarms
Ready to enhance your neonatal care? Request your YG1817 quote – where medical innovation meets newborn safety. Our clinical specialists will help customize the perfect configuration for your facility’s needs.
Technical Specifications
Model | YG1817 |
Electrical requirement | ~ 220V 50Hz or ~ 230V 60Hz |
Power consumption | ≤770VA |
Air mode temperature range | 25.0°C~37.0°C |
Over temperature alarm | <38.0°C |
High mode temperature range | 37.1°C ~ 38.0°C |
High mode temperature alarm | <39.0°C |
Temperature deviation alarm | ±1.0°C |
Skin sensor accuracy | ≤±0.3°C |
Mattress temperature Uniformity | ≤2.0°C |
Heating rate | ≤30min |
APGAR timing | 1 min. 5min. 10min |