The Veterinary Chemistry Analyzer YG1684 is a cutting-edge biochemical analyzer designed to meet the specific needs of veterinary laboratories and clinics. With its capacity to conduct species-specific diagnostic tests across 12 animal species, including both predefined and customizable profiles, this analyzer stands out for its versatility and precision. The advanced bichromatic optical system operates across 7 wavelengths, delivering both kinetic and endpoint assay results with real-time reaction curve displays. The 7-inch color LCD screen and compatibility with USB keyboards and mice make the YG1684 user-friendly. It offers robust data management capabilities with storage for up to 3000 sample results, available for output via internal or external printers and SD card export, making it an essential piece of equipment for modern veterinary practices.

Market Price

The Veterinary Chemistry Analyzer YG1684 is priced competitively within the high-quality veterinary diagnostic equipment market. Typically, similar analyzers range from approximately USD 2000 to USD 2800, positioning the YG1684 as a cost-effective yet premium solution for veterinary diagnostic needs.

Frequently Asked Questions

  • What species are supported by the YG1684?
    The analyzer supports testing for up to 12 animal species, including 8 predefined species and 4 customizable entries, ensuring flexibility across various clinical settings.
  • Is it possible to update or customize the analyzer?
    Yes, the YG1684 allows for easy system updates via SD card and enables users to customize up to 20 test protocols.
  • Does it have built-in quality control?
    Absolutely. The YG1684 includes an integrated quality control function to maintain consistent accuracy and reliability in test results.

Advantages and Disadvantages

Advantages:

  • Supports multi-species testing with customizable protocols.
  • High sensitivity and accuracy thanks to a bichromatic optical system.
  • User-friendly interface with real-time curve display and simple data export.

Disadvantages:

  • Regular maintenance or replacement of the halogen lamp may be required.
  • Limited to 8 fixed and 4 open animal profiles, potentially limiting exotic applications.
  • Lack of built-in refrigeration, which may be needed in high-throughput laboratories.

Product Use in the Field

The YG1684 is widely utilized in veterinary hospitals, animal research centers, and diagnostic laboratories for assessing biochemical parameters such as liver enzymes, kidney function, and electrolytes. Its requirement for a small sample volume and its high data storage capacity make it particularly valuable in high-throughput environments and routine wellness screenings. Veterinarians can quickly generate detailed, species-specific reports, enhancing diagnostic processes and improving care outcomes for a range of species including canines, felines, bovines, and equines.

Recommendations

To ensure optimal performance, regular calibration checks and proper storage in a controlled environment free from humidity and dust are recommended for the YG1684. Cleaning the flow cell and verifying the efficiency of the halogen lamp consistently can help maintain accurate absorbance readings. Maintaining backup USB devices and SD cards is advised for effective data management and seamless system updates.

Features

  • Supports up to 12 species (8 predefined, 4 customizable).
  • Real-time reaction curve display with kinetic and endpoint assays.
  • USB and SD card interfaces for easy data management.
  • Stores up to 3000 sample results.
  • Internal and external printer options for flexible output.
  • 7 wavelengths for comprehensive diagnostic coverage.
  • Color LCD for enhanced user interaction.

Technical Specifications

Model YG1684
Principle: Absorbance
Photometric Range: -0.500-3.500Abs
Resolution: 0.001Abs(displayed), 0.0001Abs(calculated)
Light Source: Halogen lamp
Wavelengths: 340,405,500,546,578,620,670nm,
1 more filter optional
Wavelength Accuracy: ±2nm
Band Width: 10nm
Carryover: <1%
Memory: 200 test parameters, up to 3000 sample results
Interface: RS-232,USB,SD card interface
Flow Cell: 25ul Metal-quartz flow cell
Cuvette Mode: 12.5mm*12.5mm cuvette optional
Temperature Control: 25 C, 30C,37 C;±0.5 C and ambient temperature
Display: 7″ color LCD(640*240 discernibility, 256 colors)
Input: USB mouse and external keyboard
Output: Build-in printer or external printer(optional)
Dimension L *W*H(mm): 460*330*190
Power Supply: AC 110V/220V. 50Hz/60Hz

Additional information

Weight 11,5 kg

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.