Description
The Salinity Refractometers YGA1507 // YGA1510 are specialized tools designed for testing the concentration of salt in water and brine, making them invaluable for quality control in various industries such as research laboratories, marine industries, and clinical settings. These refractometers provide direct readings of the specific gravity and concentration of salt in water, which is essential for monitoring water quality in environments like marine saltwater tanks or industrial fluids.
The YGA1507 model has a measurement range of 2-4% salinity (20-40ppt) and specific gravity from 1.015 to 1.030, making it ideal for accurate readings in moderate salt concentrations. The YGA1508 model covers a broader range of 0-4% salinity (0-40ppt), while the YGA1509 offers a further extension, measuring up to 10% salinity (0-100ppt). The YGA1510 focuses on high salinity levels, measuring from 0-28%, offering a broader range for various applications.
Market Price
The Salinity Refractometers YGA1507 // YGA1510 are priced affordably, with models generally ranging from $72 to $79 depending on the specific measurement range and features. This makes them an excellent investment for industries that require accurate salinity readings, including food production, marine biology, and environmental research.
Frequently Asked Questions
-
What are the typical uses for the YGA1507 // YGA1510 Salinity Refractometer?
- These refractometers are used primarily for measuring the salt concentration in water, brine, and industrial fluids. They are also used in marine tanks, for quality control in food production, and in research labs.
-
How do I calibrate the refractometer?
- Calibration is simple and can be done using a calibration solution with known salinity. Follow the manufacturer’s guidelines for best results.
-
What is the temperature range for optimal use?
- The refractometer is designed to function effectively between 50-86°F (10-30°C), and the ATC feature adjusts for temperature fluctuations within this range.
-
Do I need batteries to use the refractometer?
- No, the refractometer uses ambient light, so no batteries or external power source is required.
Advantages and Disadvantages
Advantages:
- Eco-friendly: Operates on ambient light, reducing the need for batteries.
- Accurate readings: Equipped with ATC for temperature compensation, ensuring precise results even under fluctuating conditions.
- Easy to use: Simple calibration and focusing make it ideal for both novice and experienced users.
- Versatile applications: Perfect for marine environments, food production, and industrial quality control.
Disadvantages:
- Limited measurement for higher concentrations: The YGA1507 and YGA1508 may not cover the highest salt concentrations required in some industrial applications.
- Not suitable for highly turbid solutions: The refractometer is designed for relatively clean liquids and may not provide accurate readings for solutions with high levels of particulates.
Field Use
The Salinity Refractometers YGA1507 // YGA1510 are indispensable tools in various fields. In the marine industry, they help monitor the salinity of water in aquariums and saltwater tanks, ensuring optimal living conditions for marine life. In food production, these refractometers are used to check the salt content in products like brines, sauces, and soups. Furthermore, in research and clinical laboratories, they help scientists and technicians accurately measure the salinity of solutions, which is critical in maintaining proper conditions for experiments and analysis.
Recommendations
To ensure the Salinity Refractometers YGA1507 // YGA1510 perform at their best, always store them in a cool, dry place to prevent damage from extreme temperatures or humidity. Clean the lens after each use, especially when measuring solutions with residues, to ensure clear readings. Regular calibration with a known solution will also help maintain accuracy over time.
Technical Specifications
Model | Description | Measurement Range | Min. Div. | Accuracy | ATC | ATC temp. | Material |
YGA1507 | ATC salinity 2- 4%(20ppt-40ppt) 1.015-1.030RI optical refractometer | Salinity: 2-4% (20-40ppt) Specific Gravity: 1.015-1.030sg | Salinity: 0.1%(1ppt) Specific Gravity: 0.001sg | Salinity: ±0.1%(1ppt) Specific Gravity: ±0.001sg | Yes | 50-86’F (10-30’C) | Pure aluminum |
YGA1508 | ATC salinity 0- 4%(00ppt-40ppt) 1.000-1.030RI optical refractometer | Salinity: 0-4% (0-40ppt) Specific Gravity: 1.000-1.030sg | Salinity: 0.1%(1ppt) Specific Gravity: 0.001sg | Salinity: ±0.1%(1ppt) Specific Gravity: ±0.001sg | Yes | 50-86’F (10-30’C) | Pure aluminum |
YGA1509 | ATC salinity 0- 10%(0ppt-100ppt) 1.000-1.070RI optical refractometer | Salinity: 0-10% (0-100ppt) Specific Gravity: 1.000-1.070sg | Salinity: 0.1%(1ppt) Specific Gravity: 0.001sg | Salinity: ±0.1%(1ppt) Specific Gravity: ±0.001sg | Yes | 50-86’F (10-30’C) | Pure aluminum |
YGA1510 | ATC salinity 0- 28% optical refractometer | 0-28% Salinity | 0.2 Salinity | ±0.2% Salinity | Yes | 0-30° C | Pure aluminum |