Description
The Pulsed Xenon Lamp Benchtop Spectrophotometer YG0902 is a cutting-edge instrument designed for accurate color analysis and precise spectral measurements across various industries. Developed by Kalstein with independent intellectual property, this benchtop spectrophotometer integrates advanced optical technology to deliver superior performance in research and quality control environments. Featuring a 7-inch TFT capacitive touchscreen display, a concave grating system, and a high-precision double-array CMOS sensor, the YG0902 ensures stable, repeatable, and high-resolution color measurements.
This spectrophotometer supports multiple measurement modes, including reflectance d/8 and transmittance d/0 geometry, both with options to include or exclude UV light. It features an automatic aperture recognition system, allowing users to switch between three different measuring apertures (Φ25.4mm, 8mm, and 4mm) or even customize them based on specific needs. Its 360nm-780nm wavelength range, with a built-in 400nm UV cut-off, ensures highly accurate UV-visible spectrophotometry. Additionally, the YG0902 includes a built-in temperature sensor, a high-capacity data storage system for up to 20,000 test results, and PC software with extended functionalities, making it an ideal tool for R&D laboratories, quality control, and industrial color analysis applications.
Market Price
The Pulsed Xenon Lamp Benchtop Spectrophotometer YG0902 is positioned in the premium spectrophotometer market, with prices typically ranging between $10.409 and $10.420 USD, depending on the model configuration and accessories included. This investment reflects the high-performance optical system, advanced calibration capabilities, and extensive data analysis features that distinguish this spectrophotometer from conventional models. Laboratories and industries requiring accurate color measurements, high stability, and versatile functionality will find the YG0902 a valuable and reliable tool for long-term use.
Frequently Asked Questions
- What industries benefit most from the YG0902 spectrophotometer?
This spectrophotometer is widely used in plastics, electronics, paints and inks, printing, garments, leather, paper, automotive, medical, cosmetics, and food industries, as well as in scientific research laboratories. - Can the YG0902 measure both reflectance and transmittance?
Yes, it features d/8 reflective and d/0 transmissive optical geometries, supporting a wide range of color analysis applications. - Does this model include a built-in UV filter?
Yes, the YG0902 has a 400nm UV cut-off Xenon lamp, making it highly effective for UV-visible spectrophotometry. - What is the data storage capacity of the YG0902?
The device can store up to 20,000 test results, ensuring ample space for laboratory data management.
Advantages and Disadvantages
Advantages:
- Advanced pulsed Xenon lamp technology for long-lasting, stable illumination
- Reflectance and transmittance measurement modes for versatile applications
- 7-inch TFT capacitive touchscreen display for easy navigation and control
- Automatic aperture recognition system with customizable measurement sizes
- Wide wavelength range (360nm-780nm) with a built-in 400nm UV cut-off
Disadvantages:
- Higher initial cost compared to basic spectrophotometers
- Requires trained personnel to maximize its full potential
- Bulky size (370×300×200mm, 9.6kg), requiring dedicated bench space
Product Use in the Field
The Pulsed Xenon Lamp Benchtop Spectrophotometer YG0902 is a highly versatile tool for laboratories requiring precise and repeatable color measurements. It is widely used in R&D, quality control, and industrial color matching applications to ensure product consistency and compliance with colorimetric standards. In plastic manufacturing, the YG0902 helps in assessing color stability across different materials, while in the automotive industry, it ensures color uniformity in coatings and paints. Cosmetics and pharmaceutical industries also benefit from its ability to analyze the shade variations in formulations.
Recommendations
To maintain optimal performance, it is recommended to regularly calibrate the spectrophotometer using the built-in calibration system, ensuring accurate and repeatable measurements. Keeping the optical components clean prevents interference with light transmission, while storing the device in a temperature-controlled environment helps maintain measurement consistency. Users should utilize the PC software for data analysis, ensuring comprehensive quality control reporting. For those requiring customized measurement apertures, using the optional accessories will enhance flexibility and precision in specialized applications.
Technical Specification
Model | YG0902 |
Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003) | |
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE |
Transmittance: SCI&SCE | |
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
Observer Angle | 2° & 10° |
Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7″ TFT Capacitive Screen-touch Display |
Data Port | USB & Print serial port |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
Optional Accessory | Micro-printer, Transmissive Test Clamp Component,Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Notes: The specifications are subject to change without notice. |