Description
The Patient Monitor YG1676 is a high-quality, full modular multi-parameter monitor, designed to ensure accurate and efficient monitoring in various medical environments, including ICU and Operating Rooms. Featuring a 12.1-inch LCD screen, this monitor is capable of tracking essential parameters such as ECG, SpO2, Respiration, NIBP, Heart Rate (PR), and Temperature (TEMP). It comes with standard configurations that include 5-lead ECG, Dual-Temp, NIBP, and SpO2 monitoring, ensuring comprehensive and real-time data for patient care.
Frequently Asked Questions
- What parameters does the YG1676 monitor track?
The YG1676 tracks a wide array of parameters, including ECG, SpO2, Temperature, Heart Rate, Respiration Rate, and NIBP, making it suitable for comprehensive patient monitoring. - Is the YG1676 suitable for both adult and pediatric patients?
Yes, the YG1676 is designed to be used for both adult and pediatric patients, providing accurate readings and reliable performance across various patient types. - Can I customize the YG1676 for additional features?
Yes, the YG1676 offers customizable options such as a 12-lead ECG, EtCO2, and even the touch screen, allowing for tailored configurations based on your specific monitoring needs.
Advantages and Disadvantages
Advantages:
-
Comprehensive Monitoring: Tracks multiple critical parameters including ECG, SpO2, NIBP, and Respiration, offering a full spectrum of data for patient care.
-
Customizable Configurations: Offers a variety of customizable options, such as a 12-lead ECG and EtCO2, to meet the unique requirements of different medical environments.
-
User-Friendly Interface: The large 12.1-inch LCD screen and intuitive interface make operation easy, even in fast-paced settings like ICUs and Operating Rooms.
Disadvantages:
-
High Initial Cost: With its advanced features and capabilities, the YG1676 may not be the most affordable option for smaller healthcare facilities.
-
Training Required: Due to the range of features and settings, healthcare staff may need some time to familiarize themselves with the system.
-
Size: Its size and complexity might require a dedicated space in medical environments, making it less suited for portable use.
Product Use in the Field
The YG1676 is ideal for use in critical care settings, particularly in ICUs and Operating Rooms where precise and real-time monitoring of patients’ vital signs is essential. It is designed to monitor adult and pediatric patients in a variety of clinical scenarios, ensuring accurate and continuous tracking of their heart rate, respiration, blood pressure, and temperature. The ECG feature, available in both 3-lead and 5-lead configurations, provides healthcare professionals with valuable insights into a patient’s heart activity, while the SpO2 and NIBP measurements offer a complete understanding of a patient’s respiratory and circulatory health.
Recommendations
To maximize the performance of the YG1676, regular maintenance and calibration are recommended to ensure continued accuracy in patient monitoring. Familiarizing healthcare staff with the system’s advanced settings and customization options is also essential for optimal use. Additionally, it is beneficial to integrate the device with other medical systems to enhance its data output and patient management capabilities, particularly in large hospitals or clinics. Keep the system updated and ensure proper storage and care to prolong its life and functionality.
Technical Specifications
Model | YG1676 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm | |
Neo/Ped | 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 25~300bpm |
Accuracy | ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.0MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM | |
Neo/Ped | 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP
|
Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 60~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second | |
Average Time Constant | <10 Second |