Description
The Multi-Angle Spectrophotometer YG0917 // YG0918 is an advanced color measurement instrument designed for precise and consistent color evaluation on surfaces affected by different viewing angles and lighting conditions. Ideal for applications in metallic, pearlescent, and complex special effect coatings, this Kalstein device offers 8 or 12 measurement angles, allowing for accurate results on curved surfaces, ensuring high precision and stability.
Market Price
The YG0917 // YG0918 Multi-Angle Spectrophotometer falls within the high-end price range, typically between $19.286 and $29.762 USD, depending on model specifications and optional accessories such as a micro-printer or extended calibration tools. This price reflects its advanced optical system, precision engineering, and industrial-grade durability, making it a critical investment for industries requiring superior color accuracy.
Frequently Asked Questions:
-
Which industries benefit from the YG0917 // YG0918 spectrophotometer? This device is ideal for applications in automotive coatings, industrial painting, aerospace, high-end cosmetics, and other industries that require precise multi-angle color measurement.
-
What is the difference between YG0917 and YG0918?
- YG0917: Features 8 measurement angles (6 light sources, 2 receivers), suitable for standard multi-angle color analysis.
- YG0918: Offers 12 measurement angles (7 light sources, 2 receivers), providing more detailed spectral analysis for complex coatings and special finishes.
-
Does this spectrophotometer support multiple light sources? Yes, it includes light sources such as D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL5), F11 (TL84), and F12 (TL83/U30), ensuring accurate color evaluations under different lighting conditions.
Advantages and Disadvantages
Advantages:
- Multi-angle measurement (8 or 12 angles) for comprehensive color analysis.
- Concave grating spectrophotometric technology for higher resolution and accuracy.
- Full-spectrum LED light source with blue enhancement for stable spectral distribution.
- Built-in color camera for accurate positioning and improved efficiency.
Disadvantages:
- Higher price point compared to basic spectrophotometers.
- Requires periodic calibration to maintain optimal accuracy.
Field Applications
The YG0917 // YG0918 Multi-Angle Spectrophotometer is essential for industries requiring precise multi-angle color analysis, such as automotive coatings, industrial painting, aerospace, and high-end cosmetics. It ensures consistent color quality by accurately measuring color variations under different viewing angles and lighting conditions.
In real-world applications, this spectrophotometer helps manufacturers maintain strict color quality standards, reducing color inconsistencies between production batches and ensuring that final products meet customer expectations.
Recommendations
To maximize performance, regular calibration with the integrated white board and black light trap is recommended. For high-volume color testing, upgrading with a micro-printer and extended calibration accessories can further enhance workflow efficiency.
Technical parameters
Model | YG0917 | YG0918 |
Measurement Geometry | 8 measurement angles (6 illumination sources, 2 receivers) | 12 measurement angles (7 illumination sources, 2 receivers) |
Measure Angle | 45° Receiver: | 45° Receiver: |
45as-15°,45as15°,45as25°,
45as45°,45as75°,45as110° |
45as-15°,45as15°,45as25°,
45as45°,45as75°,45as110° |
|
15°Receiver: | 15°Receiver: | |
15as-45°,15as-15° | 15as-45°,15as-15°,15as15°,15as-30°,15as45°,15as80° | |
Conform to the standards:ASTM D 2244,E 308,E 1164,E 2194,
E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4 |
Conform to the standards:ASTM D 2244,E 308,E 1164,E 2194,
E2539,DIN 5033,5036,6174,6175-1,6175-2;ISO 7724, 11664-4 |
|
SAE J 1545 | SAE J 1545 | |
Application | Provide accurate and consistent color measurement for metallic,
pearlescent and other complex special effect color products |
Provide accurate and consistent color measurement for metallic,
pearlescent and other complex special effect color products |
Light Source | Full spectrum LED light source with blue enhancement | Full spectrum LED light source with blue enhancement |
Lamp Life | 5 years, 3 million times measurements | 5 years, 3 million times measurements |
Spectrophotometric Mode | Concave Grating | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 400nm-700nm | 400nm-700nm |
Wavelength Interval | 10nm | 10nm |
Measurement Range | 0~600% | 0~600% |
Semiband Width | 10nm | 10nm |
Measuring Aperture | Φ12mm | Φ12mm |
Color Space | CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99 | CIE LAB,XYZ,Yxy,LCh,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*94,ΔE*cmc(2:1),
ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE DIN6175 |
ΔE*ab,ΔE*94,ΔE*cmc(2:1),
ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE DIN6175 |
Other Colorimetric Index | Flop Index, Int-Em | Flop Index, Int-Em |
Observer Angle | 2°/10° | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,
F2(CWF),F3,F4,F5,F6,F7(DLF), F8,F9,F10(TPL5),F11(TL84), F12(TL83/U30) |
D65,A,C,D50,D55,D75,F1,
F2(CWF),F3,F4,F5,F6,F7(DLF), F8,F9,F10(TPL5),F11(TL84), F12(TL83/U30) |
Display | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color simulation, Sample effect value, Effect difference value | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color simulation, Sample effect value, Effect difference value |
Measuring Time | Approx. 1 second for one angle | Approx. 1 second for one angle |
Approx. 8 seconds for all angles | Approx. 12 seconds for all angles | |
Repeatability | Spectral reflectance: Standard deviation within 0.08% | Spectral reflectance: Standard deviation within 0.08% |
Chromaticity value: ΔE*ab 0.03 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | Chromaticity value: ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Reproducibility | ΔE*<0.10,avg on the gray tile of BCRA tile set | ΔE*<0.10,avg on the gray tile of BCRA tile set |
ΔE*<0.25,avg on the color BCRA tile set | ΔE*<0.25,avg on the color BCRA tile set | |
Inter-instrument Error | 0.18ΔE*00(avg on reference Series II BCRA tile set) | 0.18ΔE*00(avg on reference Series II BCRA tile set) |
Effect Parameters | Sparkle Grade(SG),Diffuse coarseness(DC) and Color Variation(CV) | Sparkle Grade(SG),Diffuse coarseness(DC) and Color Variation(CV) |
Effect Measurement | 6 angles Sparkle Grade(SG),Color Variation(CV):15as-45°,15as-30°,15as-15°,15as15°,15as45°,15as80° | 6 angles Sparkle Grade(SG),Color Variation(CV):15as-45°,15as-30°,15as-15°,15as15°,15as45°,15as80° |
15d Diffuse coarseness(DC) | 15d Diffuse coarseness(DC) | |
Effect Repeatability | Sparkle Grade(SG) Short-term repeatability: 0.12% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration) | Sparkle Grade(SG) Short-term repeatability: 0.12% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration) |
Diffuse coarseness(DC) Short-term repeatability:e0.09% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration) | Diffuse coarseness(DC) Short-term repeatability:e0.09% (10 times standard deviations) (When a color plate is measured 10 times at 10 second intervals after white calibration) | |
Effect Reproducibility | Sparkle Grade(SG) Reproducibility: 1.9% (10 times standard deviations) | Sparkle Grade(SG) Reproducibility: 1.9% (10 times standard deviations) |
(avg on reference Series II BCRA tile set) | (avg on reference Series II BCRA tile set) | |
Diffuse coarseness(DC) Reproducibility: 1.4% (10 times standard deviations)(avg on reference Series II BCRA tile set) | Diffuse coarseness(DC) Reproducibility: 1.4% (10 times standard deviations)(avg on reference Series II BCRA tile set) | |
Trigger mode | Pressure sensing trigger, button trigger, software trigger | Pressure sensing trigger, button trigger, software trigger |
Measuring Mode | Single measurement, average measurement (1-99), continuous measurement (1-99) | Single measurement, average measurement (1-99), continuous measurement (1-99) |
Locating Mode | Color camera preview | Color camera preview |
Dimension | L*W*H=195X83X128mm | L*W*H=195X83X128mm |
Weight | About 1Kg | About 1Kg |
Power | lithium-ion battery, 3.7V,3200mAh, Continuous test 6000 times within 8 hours of full charge | lithium-ion battery, 3.7V,3200mAh, Continuous test 6000 times within 8 hours of full charge |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen | 3.5-inch TFT color LCD, Capacitive Touch Screen |
Interface | USB, Bluetooth 5.0 | USB, Bluetooth 5.0 |
Data Storage | 1000 pcs Standards,4000 pcs Samples | 1000 pcs Standards,4000 pcs Samples |
Language | Simplified Chinese, Traditional Chinese, English | Simplified Chinese, Traditional Chinese, English |
Operating Environment | 10℃ to 50℃, humidity does not exceed 85%, no condensation | 10℃ to 50℃, humidity does not exceed 85%, no condensation |
Storage Environment | -20℃ to 50℃, humidity does not exceed 85%, no condensation | -20℃ to 50℃, humidity does not exceed 85%, no condensation |
Calibration | Built-in white board parameters, external white board, black light trap, color board | Built-in white board parameters, external white board, black light trap, color board |
Calibration Interval | 4 hours,8 hours,24 hours,Startup calibration | 4 hours,8 hours,24 hours,Startup calibration |
Standard accessories | Power Adapter, USB Cable, User Guide,PC Software(download from the official website), Calibration Board, black light trap,Protective cap, wristband | Power Adapter, USB Cable, User Guide,PC Software(download from the official website), Calibration Board, black light trap,Protective cap, wristband |
Optional Accessory | Micro-printer | Micro-printer |
Notes | Technical parameters are for reference only, subject to actual sales products. | Technical parameters are for reference only, subject to actual sales products. |