- This device features a human-machine interactive menu with dynamic, real-time display of sample IDs. It includes automatic liquid level detection and alarms, along with real-time diagnostics of system status. It efficiently detects and filters tiny bubbles to prevent clogs and ensure precise measurements. The wave theory flushing method and direct flushing pipe method help avoid blockages and cross-contamination.
- The instrument performs automatic calibration and two-point correction, offering print-outs of QC graphs and statistical parameters. Power failure protection prevents data loss, and the device supports fuzzy queries, LIS software, and selectable data upload formats. It also supports RTC clock management and can be powered off anytime to reduce reagent consumption, making it suitable for various hospitals.
Technical specifications
Model | YR06407 | YR06408 | YR06409 | YR06410 | YR06411 |
Sample | serum, plasma, whole blood and dilute urine | ||||
Storage | up to 10000 test results | ||||
Printer | Internal thermal printer | ||||
Interface | RS232 port | ||||
Analysis Method | ion selective electrode (ISE) | ||||
Measuring speed | <30s | ||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | ||||
Temperature | 5-40°C | ||||
Relative Humidity | <80% | ||||
Atmospheric pressure | 86~106 kPa | ||||
Power supply | AC220V±22V, 50Hz±1Hz | ||||
Power | <120W | ||||
Test Parameters | K Na Cl | K Na Cl TCO AG | K Na Cl iCa nCa TCa pH | K Na Cl iCa nCa TCa pH TCO AG | K Na Cl Li |
Model | YR06412 | YR06413 | YR06414 | YR06415 | YR06416 | YR06417 |
Sample | serum, plasma, whole blood and dilute urine | |||||
Storage | up to 10000 test results | |||||
Printer | Internal thermal printer | |||||
Interface | RS232 port | |||||
Analysis Method | ion selective electrode (ISE) | |||||
Measuring speed | <30s | |||||
Sample position | 39 positions (including 5 emergency and 4 functional positions) | |||||
Temperature | 5-40°C | |||||
Relative Humidity | <80% | |||||
Atmospheric pressure | 86~106 kPa | |||||
Power supply | AC220V±22V, 50Hz±1Hz | |||||
Power | <120W | |||||
Test Parameters | K Na Cl iCa nCa TCa pH Li | K Na Cl iCa nCa TCa pH Li TCO AG | K Na Cl iCa nCa TCa pH Mg | K Na Cl iCa nCa TCa pH Mg TCO AG | K Na Cl iCa nCa TCa pH Mg Li TCO AG |
K Na Cl iCa nCa TCa pH Mg Li
|
Accessories
Model | Description |
YRA264 | K Electrode |
YRA265 | K Electrode |
YRA266 | Cl Electrode |
YRA267 | Ca Electrode |
YRA268 | pH Electrode |
YRA269 | Li Electrode |
YRA270 | Mg Electrode |
YRA271 | Ref. Electrode |
YRA272 | Reagent Pack Calibration A 430ml; Calibration B 110ml; ( For Model H900 only) |
YRA273 | Reference Electrode Internal Solution – 10ml |
YRA274 | Electrode Internal
Solution – 3ml |
YRA275 | Activating Solution – 110ml |
YRA276 | QC Solution Level 2
(Water-based) – 110ml |
YRA277 | Cleaning Solution – 110ml |
YRA278 | Electrode Wash Solution (Protein Enzyme) -125mg (25mg/bottle x5) |
YRA278-1 | Electrode Wash Solution (Diluent) – 5ml ( 1 bottle) |