Benchtop Spectrophotometer YG0905

ManufacturerYUL GARY

Description

The Benchtop Spectrophotometer YG0905 is a high-precision instrument designed to deliver accurate color measurement and quality control in a variety of industries, including plastics, electronics, paints and inks, textiles, printing, garments, and cosmetics. This advanced desktop spectrophotometer can accurately calculate and express color differences using multiple color spaces and formulas, ensuring consistent and repeatable results. Its built-in temperature sensor compensates for environmental variations, providing greater accuracy and stability in every measurement.

Equipped with a 7-inch TFT capacitive touchscreen, the YG0905 offers an intuitive and user-friendly interface, making it easy to navigate through its multiple measurement modes, including Quality Management Mode and Sample Mode. The double-array 256-image CMOS sensor combined with a concave grating system ensures high-resolution spectral readings across a wavelength range of 360-780nm. This spectrophotometer supports fluorescent sample testing, making it an ideal choice for advanced color analysis in R&D, manufacturing, and laboratory environments.

Market Price

The Benchtop Spectrophotometer YG0905 is positioned as a high-end spectrophotometric device, with prices typically ranging between $9.859 and $9.880 USD, depending on configuration, accessories, and software packages. This price range reflects the premium quality components, high-accuracy measurement capabilities, and extended lifespan of the xenon lamp (up to 5 million measurements). Laboratories and industries looking for a reliable solution for precise color management and quality control will find the YG0905 a valuable investment that ensures compliance with colorimetric standards.

Frequently Asked Questions

  • What industries benefit from the YG0905 spectrophotometer?
    The YG0905 is widely used in plastics, paints, textiles, automotive, printing, food, and medical industries, as well as in research laboratories for precise color analysis and quality assurance.
  • Does this spectrophotometer support fluorescent sample testing?
    Yes, the YG0905 includes fluorescent sample testing capabilities, making it suitable for high-accuracy UV-visible spectrophotometry.
  • Can this model measure both solid and liquid samples?
    Yes, the YG0905 features both reflective (d/8°) and transmissive (d/0°) optical geometries, allowing for accurate measurement of solid, translucent, and liquid samples.
  • What is the storage capacity of the YG0905?
    This device can store up to 20,000 test results, making it ideal for laboratories requiring large-scale data collection and long-term analysis.

Advantages and Disadvantages

Advantages:

  • Advanced optical system with high-precision color measurement
  • 7-inch TFT touchscreen for easy operation and intuitive navigation
  • Automatic aperture detection system for versatile sample measurement
  • Long-life LED and Xenon lamps (up to 5 million measurements)
  • Wavelength range of 360-780nm, with fluorescent sample testing capabilities

Disadvantages:

  • Higher initial investment compared to basic spectrophotometers
  • Requires trained personnel to utilize all advanced functionalities

Product Use in the Field

The Benchtop Spectrophotometer YG0905 is widely used in R&D laboratories, industrial production lines, and quality control departments, ensuring that color consistency is maintained across different production batches. It is a key tool in printing and textile industries, helping manufacturers match colors accurately and maintain quality standards. In automotive applications, the YG0905 is used for coating and paint analysis, while in cosmetics and packaging, it ensures uniformity in product coloration. Medical and pharmaceutical industries benefit from its highly accurate transmittance and reflectance measurements, making it indispensable for sample evaluation and research applications.

Recommendations

To maintain optimal performance, it is recommended to regularly calibrate the YG0905 using its built-in automatic calibration system. Cleaning the optical components periodically prevents light transmission errors, while operating the device in a stable, temperature-controlled environment ensures consistent results. Users should take advantage of the PC software for data analysis, allowing for detailed tracking of color variations and quality control reports. For those requiring specialized measurements, optional customized apertures and accessories can enhance precision and adaptability.

Technical Specifications

Model YG0905
Optical Geometry Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         

SCI (specular component included)/SCE (specular component excluded) ;                                          

Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) 

SCI (specular component included)/SCE (specular component excluded)

Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7

Application It is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size Φ154mm
Light Source 360 nm to 780 nm, Combined LED Light (5 million life span)
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360-780nm
Wavelength Interval 10nm
Semiband Width 10nm
Measured Reflectance Range 0-200%
Measuring Aperture Reflective : Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;                         
Remark: 1. Automatic identification of switch caliber   2. Customized Configuration caliber and lens position
Specular Component Reflectance: SCI&SCE  / Transmittance: SCI&SCE
Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter)
Other Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle 2°/10°
Illuminant D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed Data Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time About 2.4s (Measure SCI & SCE about 5s)
Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.05%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% (400 nm to 700 nm: within 0.06%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.15  (Average for 12 BCRA Series II color tiles)
Dimension L*W*H=370x300x200mm
Weight Approx. 9.6kg
Power AC 24V, 3A Power adapter power supply
Illuminant Life Span 5 years, more than 3 million times measurements
Display 7-inch TFT color LCD, Capacitive Touch Screen
Data Port USB & Print serial port
Data Storage Standard 1000 Pcs, Sample 20000 Pcs
Language Simplified Chinese, Traditional Chinese, English,
Operating Environment 0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment -20~50℃, 0~85%RH (no condensing)
Standard Accessory Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber
Optional Accessory Micro-printer, Transmissive Test Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice. YS6003 quality management software can only be used for data management

Additional information

Weight 12,5 kg

Quote List

Quote List

No products in the list

Product categories

In this section you can select the sector or product of your interest.

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.