Help Desk

(+47) 41376523

Automatic Nucleic Acid Extractor YG1282

ManufacturerYUL GARY

Description

The Automatic Nucleic Acid Extractor YG1282 is a state-of-the-art solution that revolutionizes nucleic acid extraction for high-throughput laboratories. Integrating innovative Rotary Mixing Technology (RMT), this extractor ensures exceptional purity, accuracy, and contamination control. With the capability to process up to 96 samples per cycle, the YG1282 is designed for cost-effective molecular diagnostics, biomedical research, forensic analysis, and genetic testing, optimizing reagent use and minimizing waste efficiently.

Market Price

The YG1282 Automatic Nucleic Acid Extractor is competitively priced between $30,880 and $31,000 USD. Price variations depend on configuration, accessories, and reagent compatibility. Laboratories looking to enhance efficiency and reduce contamination will find this model an economical choice for extensive molecular testing needs.

Frequently Asked Questions

  • What are the primary applications of the YG1282?
    This extractor is tailored for high-throughput nucleic acid extraction, making it ideal for clinical diagnostics, genetic research, forensic science, and environmental testing.
  • How does the YG1282 prevent contamination?
    The system incorporates a negative pressure HEPA filtration setup, a UV disinfection module, and Rotary Mixing Technology (RMT) to significantly reduce aerosol generation and prevent false positives from cross-contamination.
  • Can the system be customized for different protocols?
    Absolutely, the YG1282 enables users to create, edit, and manage up to 1000 protocols, offering great flexibility for various applications and reagent kits.

Advantages and Disadvantages

Advantages:

  • High-throughput processing for up to 96 samples per cycle
  • Rotary mixing technology (RMT) improves purity and reduces aerosol generation
  • HEPA filtration and UV disinfection ensure contamination-free extractions
  • Hands-free operation with automatic motor-driven cabinet opening/closing
  • Customizable protocols capable of storing up to 1000 configurations
  • Intuitive operation with a 7-inch full-color LCD touchscreen

Disadvantages:

  • Higher initial investment compared to manual extraction methods
  • Requires specific reagent kits for optimal performance
  • Limited to 96 samples per run, which might not meet the needs of extremely high-volume laboratories

Field Applications

The YG1282 Automatic Nucleic Acid Extractor is extensively utilized in:

  • Clinical and Molecular Diagnostic Laboratories – Improving COVID-19, genetic disease, and infectious pathogen testing
  • Forensic and Genetic Identification Labs – Facilitating DNA and RNA extractions for forensic investigations
  • Biotech and Pharmaceutical Research – Assisting in drug discovery, gene sequencing, and biomarker analysis
  • Food Safety and Environmental Testing – Aiding in the detection of microbial contamination in food products and water samples

Recommendations

To maintain peak performance and longevity, users are advised to:

  • Conduct regular UV disinfection cycles to prevent contamination
  • Utilize compatible reagent kits for optimal extraction efficiency
  • Monitor HEPA filters and replace them as needed to ensure air purity
  • Keep firmware and protocol management software updated to enhance system performance

Technical Specifications

Model YG1282
Throughput 1-96
Reaction Volume 30-1000uL
Sample Volume 200uL
Compatible Consumables 96-deep-well plates
customized 6 strip tube
Inter-well Extraction Difference CV ≤3%
Rotational Speed ≤3000rpm
Heating Temperature Lysis heating: room temperature to 120°C
Elution heating: room temperature to 120°C
Mixing Method Rotary mixing
Operation Mode 7-inch full-color LCD touch screen operation
Program Storage Up to 1000 programs can be storaged
Protocol Management Flexible to create, edit and delete protocols
Automatic Control Motor-driven automatic opening and closing of the experiment cabinet
Magnetic Bead Residue ≤1%
Power Failure Protection Choose freely whether or not to continue the experiment when the power is on again after cutting off
Contamination Control Negative pressure HEPA exhaust filter module;
Built-in UV disinfection module
Connection Port Type USB port
Weight 45kg (net)
Instrument Dimensions 510mm*490mm*480mm (W*L*H)
Power Supply and Power Consumption AC 100V-240V, 50/60HZ; 600VA

Additional information

Weight 54 kg

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.