Description
The Automatic Nucleic Acid Extractor YG1282 is a state-of-the-art automated nucleic acid extraction system that leverages rotary mixing technology (RMT) to enhance purity, accuracy, and contamination control. Designed for high-throughput laboratories, this system processes up to 96 samples per cycle, making it an ideal solution for molecular diagnostics, biomedical research, forensic analysis, and genetic testing. The YG1282 is compatible with 96-deep-well plates and customized six-strip tubes, ensuring efficient reagent usage while reducing waste and processing time.
Equipped with a 7-inch full-color LCD touchscreen, the YG1282 offers intuitive operation, allowing users to create, edit, and manage protocols with ease. The negative pressure ventilation system with a HEPA filtration module ensures that extracted air remains free of biohazards, while the built-in UV disinfection module minimizes cross-contamination risks. Additionally, the system’s motor-driven automatic opening and closing of the experiment cabinet streamlines operations, providing hands-free functionality for maximum convenience.
Market Price
The YG1282 Automatic Nucleic Acid Extractor is available within a price range of $30.880 to $31.000 USD, depending on configuration, accessories, and reagent compatibility. Laboratories looking to optimize efficiency and minimize contamination risks will find this model to be a cost-effective solution for large-scale molecular testing. To receive an accurate quote, request a personalized price estimate through Kalstein Plus.
Frequently Asked Questions
- What are the primary applications of the YG1282?
This model is designed for high-throughput nucleic acid extraction, making it suitable for clinical diagnostics, genetic research, forensic science, and environmental testing. - How does the YG1282 prevent contamination?
It features a negative pressure HEPA filtration system, UV disinfection module, and rotary mixing technology (RMT) to minimize aerosol generation and false positives caused by cross-contamination. - Can the system be customized for different protocols?
Yes, the YG1282 allows users to create, edit, and manage up to 1000 stored protocols, ensuring flexibility for various applications and reagent kits.
Advantages and Disadvantages
Advantages:
- High-throughput processing with 1 to 96 samples per cycle
- Rotary mixing technology (RMT) enhances purity and minimizes aerosol formation
- HEPA filtration and UV disinfection ensure contamination-free extractions
- Automatic motor-driven cabinet opening/closing for a hands-free operation
- Customizable protocol management with up to 1000 saved protocols
- 7-inch full-color LCD touchscreen for easy and efficient operation
Disadvantages:
- Higher initial investment compared to manual extraction methods
- Requires specific reagent kits for optimal performance
- Limited to 96 samples per run, which may not be suitable for extremely high-volume laboratories
Field Applications
The YG1282 Automatic Nucleic Acid Extractor is widely used in:
- Clinical and Molecular Diagnostic Laboratories – Enhancing COVID-19, genetic disease, and infectious pathogen testing
- Forensic and Genetic Identification Labs – Supporting DNA and RNA extractions for forensic investigations
- Biotech and Pharmaceutical Research – Facilitating drug discovery, gene sequencing, and biomarker analysis
- Food Safety and Environmental Testing – Ensuring microbial contamination detection in food products and water samples
Recommendations
To maintain peak performance and longevity, users should:
- Perform regular UV disinfection cycles to prevent contamination
- Use compatible reagent kits for optimal extraction efficiency
- Monitor HEPA filters and replace as needed to maintain air purity
- Keep firmware and protocol management software updated for enhanced system performance
Technical specifications
Model | YG1282 |
Throughput | ene-96 |
Reaction Volume | 30-1000uL |
Sample Volume | 200uL |
Compatible Consumables | 96-deep-well plates |
customized 6 strip tube | |
Inter-well Extraction Difference | CV ≤3% |
Rotational Speed | ≤3000rpm |
Heating Temperature | Lysis heating: room temperature to 120°C |
Elution heating: room temperature to 120°C | |
Mixing Method | Rotary mixing |
Operation Mode | 7-inch full-color LCD touch screen operation |
Program Storage | Up to 1000 programs can be storaged |
Protocol Management | Flexible to create, edit and delete protocols |
Automatic Control | Motor-driven automatic opening and closing of the experiment cabinet |
Magnetic Bead Residue | ≤1% |
Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
Contamination Control | Negative pressure HEPA exhaust filter module; |
Built-in UV disinfection module | |
Connection Port Type | USB port |
Weight | 45kg (net) |
Instrument Dimensions | 510mm*490mm*480mm (W*L*H) |
Power Supply and Power Consumption | AC 100V-240V, 50/60HZ; 600VA |