Help Desk

(+47) 41376523

Automatic Nucleic Acid Extractor YG1280-1

ManufacturerYUL GARY

Description

The Automatic Nucleic Acid Extractor YG1280-1 is designed for cutting-edge molecular diagnostics and genetic research. This state-of-the-art device delivers rapid, efficient, and contamination-free nucleic acid extraction through its innovative Rotary Mixing Technology (RMT). Capable of processing up to 16 samples simultaneously, it offers flexible throughput options, ensuring high yield and superior purity. Its compact design makes it suitable for various laboratory needs, providing both efficiency and quality for demanding applications.

Market Price

The YG1280-1 Automatic Nucleic Acid Extractor is available in the market within the price range of $8,880 to $9,000 USD, contingent on the chosen configuration and optional features. This investment underlines the advanced technology and automated capabilities that significantly boost laboratory productivity.

Frequently Asked Questions

  • What is the primary use of the YG1280-1 Nucleic Acid Extractor?
    The system is intended for automated, high-purity nucleic acid extraction, making it ideal for applications like clinical diagnostics, genetic testing, microbiology, and forensic analysis.
  • Can this device be operated remotely?
    Yes, the YG1280-1 supports Wi-Fi connectivity and mobile app control, allowing users to initiate and monitor experiments via smartphones or tablets.
  • What contamination control measures are included?
    The system incorporates advanced UV sterilization, ozone disinfection, HEPA filtration, and negative pressure mechanisms to ensure minimal cross-contamination and maintain sample integrity.

Advantages and Disadvantages

Advantages:

  • 16-sample throughput, perfect for labs with diverse sample needs.
  • RMT for optimized lysis and elution efficiency.
  • Automated reagent detection and protocol configuration, reducing user intervention.
  • Multiple control options include a touchscreen interface and mobile app remote management.
  • Comprehensive contamination control measures ensure sample purity.
  • Compact size suitable for placement within biosafety cabinets.

Disadvantages:

  • Higher initial cost compared to manual extraction methods.
  • Demands regular maintenance for peak performance and durability.
  • Limited 16-sample capacity per run may not suffice for high-throughput labs.

Field Applications

The YG1280-1 Nucleic Acid Extractor finds extensive use in:

  • Molecular Diagnostics: Processes clinical samples for genetic analysis and infectious disease screening.
  • Forensic Science: Extracts DNA from biological samples for forensic investigations.
  • Veterinary Research: Identifies pathogens and genetic markers in animal studies.
  • Pharmaceutical and Biotech Laboratories: Assists in R&D for drugs and genetic engineering.
  • Food and Environmental Safety: Detects microbial contaminants and genetic modifications in food products.

Recommendations

To maximize efficiency and extend usage lifespan, laboratories should:

  • Regularly update software for enhanced performance.
  • Carry out routine maintenance on HEPA filters, UV lamps, and ozone disinfection systems.
  • Utilize compatible 96-deep-well plates and 6-strip tubes for effective sample processing.
  • Ensure consistent monitoring of the mixing sleeve status to prevent mechanical obstructions.

Technical Specifications

Model YG1280-1
Throughput 16
Processing Volume 20-1700μL
Sample Processing Volume 200-500μL
Compatible Consumables Customized 96-deep-well plates, single 6-strip tubes
Inter-well Difference CV≤3%
Mixing Method Rotary mixing
Rotary Speed 100~3000rpm
Temperature Control Range Temperature control separately for lysis and elution.
Temperature range from 30°C to 120°C.
Temperature Control Accuracy Heating speed: 4.0±0.2°C/s.
Temperature accuracy: ±1.0°C.
Temperature uniformity:≤1.0°C.
Languages Chinese/English
Protocol Management Flexible to create, edit and delete protocols
Operation Mode Mode 1: Android systems in smartphones/tablets
Mode 2: 6.86 inch full-color LCD screen
Automatic Control Automatic opening and closing of the experiment cabin
Reagent Identification Automatic identification of reagent information and running the assays
Mixing Sleeve Monitoring Real-time monitoring of the mixing sleeves status in experiment
Magnetic Bead Residue ≤1%
Power Failure Protection Choose freely whether or not to continue the experiment when the power is on again after cutting off
Disinfection Ozone + UV disinfection
Auto Power-off Auto power-off after UV disinfection
Negative-Pressure Filtration Negative pressure HEPA filtration module
Connection Port Type USB port
Weight 7.4Kg (net)
Instrument Dimensions 210mm(L)*229mm(W)*242mm(H)
Power Supply AC220V, 50Hz

Additional information

Weight 11 kg

Quote List

Quote List

No products in the list

Product categories

FAQ

Do you need help?

If you have any questions before processing the order, take a look at the most frequently asked questions

Do you want to know the cost of air shipping to your establishment?

Place your address in the payment area and you will automatically see the shipping to your door!

I am an institution; I need to know the price for several units; I would like to know the cost of the maritime freight

Request a custom quote in the contact section once you identify the model.