Description
Hematology reagents are indispensable for ensuring accurate and efficient results when using hematology analyzers. These reagents play a critical role in a variety of tests, including hemolytic agents, diluents, and cleaning solutions. Specifically, the Hematology Reagents YGA1301 // YGA1303 range includes a selection of products designed to support the functionality of both 3-part and 5-part differential hematology analyzers. The reagents include hemolytic agents that are crucial for destroying red blood cells (RBCs) to ensure accurate white blood cell (WBC) counts, performing WBC classifications, and facilitating hemoglobin (HGB) detection. The diluent helps maintain the volume and shape of cells, providing an optimal conductive environment for testing. Additionally, cleaning solutions and concentrated cleaning solutions are essential for maintaining the analyzer’s pipes, needles, and counting pools, ensuring consistent performance.
The Hematology Reagents YGA1301 // YGA1303 are engineered for precision and consistency, offering a wide range of applications across clinical settings. With carefully designed formulations, they ensure smooth operation and long-lasting reliability for labs performing routine blood tests. The reagents come in different quantities to meet varying laboratory needs, with packages designed for high-volume, daily use. The startup consumption for these reagents ranges from 4 to 18 ml, with the annual consumption depending on the number of tests performed, making it a flexible choice for different laboratory sizes and usage patterns.
Market Price
The Hematology Reagents YGA1301 // YGA1303 are competitively priced within the market, with costs ranging from approximately $49 to $300 per reagent set, depending on the specific reagent and the quantity purchased. Prices may vary based on the supplier and any ongoing promotions. This price range reflects the high-quality standards and performance required in clinical environments.
Frequently Asked Questions
- What is the recommended daily usage of these reagents?
The reagents are designed for continuous use with a daily consumption of approximately 60 tests for the YGA1301 reagent. The consumption of reagents will vary depending on the specific tests conducted, but this daily consumption ensures efficient and reliable operation. - How often should I replace these reagents?
The reagents should be replaced according to the total test quantity per year. For example, the YGA1301 reagent requires approximately 39 units per year, making it an easy product to monitor and reorder based on consumption. - Are these reagents compatible with all hematology analyzers?
Yes, these reagents are compatible with the majority of 3-part and 5-part differential hematology analyzers on the market, making them a versatile choice for a wide range of laboratories.
Advantages and Disadvantages
Advantages:
- High Compatibility: Suitable for a wide range of hematology analyzers, including both 3-part and 5-part differential models.
- Precise Formulation: Ensures accurate test results, which is critical for reliable patient diagnosis.
- Easy to Monitor Usage: With clear consumption guidelines, labs can easily manage reagent usage.
- Cost-Effective: Competitive pricing with a focus on performance, ensuring value for money in high-volume settings.
Disadvantages:
- Regular Replacement Needed: The reagents need to be replenished regularly based on the total test quantity, which requires ongoing purchasing.
- Annual Reagent Consumption: Larger labs with high test volumes may require bulk purchases to keep up with the annual reagent demand.
Use in the Field
The Hematology Reagents YGA1301 // YGA1303 are extensively used in hospitals, clinics, and diagnostic labs where routine blood tests are conducted. These reagents help ensure that hematology analyzers function at peak performance, facilitating accurate and quick results in blood analysis. They are crucial for WBC counts, RBC destruction, and hemoglobin detection, ensuring that diagnostic labs can provide essential health insights with minimal downtime.
Recommendations
To maximize the performance and lifespan of Hematology Reagents YGA1301 // YGA1303, it is essential to follow proper storage and handling procedures. Keep reagents in a cool, dry place, and ensure that they are used within the recommended shelf life. Regular calibration and maintenance of your hematology analyzer will also ensure the most accurate results. By staying on top of reagent replenishment and proper equipment care, you will maintain the efficiency and reliability of your laboratory’s testing processes.
Technical Description
Model Item | YGA1301 | YGA1302 | YGA1303 |
Start up(ml) | 18 | 15 | 4 |
Shut down(ml) | 18 | 0 | |
Per Test (ml) | 35 | 10 | 0,6 |
Daily Sample | 60 | ||
Total Test Quantity per Year | 21900 | ||
Days | 365 | ||
Start up and shutdown consumption per year | 13140 | 5475 | 1460 |
Test Consumption | 766500 | 219000 | 13140 |
Reagent package needed per year | 39 | 44,9 | 29,2 |
Aditional Information | Diluent 20L | Cleaner 5L | Lyse 500mL |
Note: Probe cleaner is used as maintenance reagent. The total consumption should be estimated |