The Automatic Nucleic Acid Extractor YG1280-1 is an advanced and compact nucleic acid extraction system designed for fast, efficient, and contamination-free sample processing. Featuring Rotary Mixing Technology (RMT), this device offers flexible throughput, allowing up to 16 simultaneous extractions without interference. This innovative system ensures high extraction yields and superior purity across various applications, including molecular diagnostics, genetic research, and infectious disease detection.
With its award-winning user-friendly design, the YG1280-1 enables automated workflow execution and remote software updates, making laboratory operations seamless and efficient. The device can be controlled via a 6.86-inch touchscreen or a smartphone/tablet app, ensuring ultimate flexibility in laboratory environments. Additionally, the integrated contamination control system, which includes UV disinfection, negative-pressure HEPA filtration, and ozone sterilization, ensures safe and reliable operation.
Market Price
The YG1280-1 Automatic Nucleic Acid Extractor is available in the market for approximately $8.880 – $9.000 USD, depending on configuration, accessories, and optional software features. This pricing reflects the cutting-edge technology and automated features that significantly improve laboratory efficiency and reduce human intervention. To receive an exact price quotation, contact an authorized distributor or request an automated quote through Kalstein Plus.
Frequently Asked Questions
- What is the primary use of the YG1280-1 nucleic acid extractor?
This system is designed for automated, high-purity nucleic acid extraction, ideal for clinical diagnostics, genetic testing, microbiology, and forensic analysis. - Can this device be operated remotely?
Yes, the YG1280-1 supports Wi-Fi connectivity and mobile app control, allowing users to initiate and monitor experiments from smartphones or tablets. - What contamination control measures are included?
The system integrates UV sterilization, ozone disinfection, HEPA filtration, and negative pressure mechanisms to minimize cross-contamination and ensure sample integrity.
Advantages and Disadvantages
Advantages:
- Flexible 16-sample throughput, ideal for labs handling multiple sample types
- Rotary Mixing Technology (RMT) for optimized lysis and elution efficiency
- Automated reagent detection and protocol identification, reducing human error
- Multiple control options, including touchscreen, mobile app, and remote software updates
- Comprehensive contamination control, featuring UV, ozone, and HEPA filtration
- Compact and lightweight design, allowing placement in biosafety cabinets for highly sensitive samples
Disadvantages:
- Higher initial investment compared to manual extraction methods
- Requires routine maintenance for optimal performance and longevity
- Limited to 16-sample capacity per run, which may not be sufficient for high-throughput laboratories
Field Applications
The YG1280-1 Nucleic Acid Extractor is widely used in:
- Molecular Diagnostics – Processing clinical samples for genetic analysis and infectious disease detection
- Forensic Science – Extracting DNA from biological samples for forensic investigations
- Veterinary Research – Identifying pathogens and genetic markers in animal studies
- Pharmaceutical and Biotech Laboratories – Supporting R&D in drug development and genetic engineering
- Food and Environmental Safety – Detecting microbial contaminants and genetic modifications in food products
Its high-speed processing, automated contamination control, and flexible workflow integration make it a powerful tool for precision laboratory testing.
Recommendations
To ensure maximum efficiency and longevity, laboratories should:
- Regularly update the software for enhanced performance and compatibility with new reagent kits
- Perform routine maintenance on HEPA filters, UV lamps, and ozone disinfection systems
- Use compatible 96-deep-well plates and 6-strip tubes for optimal sample processing
- Monitor the mixing sleeve status to prevent potential mechanical obstructions
Technical specifications
Model | YG1280-1 |
Throughput | 16 |
Processing Volume | 20-1700μL |
Sample Processing Volume | 200-500μL |
Compatible Consumables | Customized 96-deep-well plates, single 6-strip tubes |
Inter-well Difference | CV≤3% |
Mixing Method | Rotary mixing |
Rotary Speed | 100~3000rpm |
Temperature Control Range | Temperature control separately for lysis and elution. |
Temperature range from 30°C to 120°C. | |
Temperature Control Accuracy | Heating speed: 4.0±0.2°C/s. |
Temperature accuracy: ±1.0°C. | |
Temperature uniformity:≤1.0°C. | |
Languages | Chinese/English |
Protocol Management | Flexible to create, edit and delete protocols |
Operation Mode | Mode 1: Android systems in smartphones/tablets |
Mode 2: 6.86 inch full-color LCD screen | |
Automatic Control | Automatic opening and closing of the experiment cabin |
Reagent Identification | Automatic identification of reagent information and running the assays |
Mixing Sleeve Monitoring | Real-time monitoring of the mixing sleeves status in experiment |
Magnetic Bead Residue | ≤1% |
Power Failure Protection | Choose freely whether or not to continue the experiment when the power is on again after cutting off |
Disinfection | Ozone + UV disinfection |
Auto Power-off | Auto power-off after UV disinfection |
Negative-Pressure Filtration | Negative pressure HEPA filtration module |
Connection Port Type | USB port |
Weight | 7.4Kg (net) |
Instrument Dimensions | 210mm(L)*229mm(W)*242mm(H) |
Power Supply | AC220V, 50Hz |