Description
The High Temperature Viscometer YG0547 // YG0550 is an advanced instrument designed for precise viscosity measurement across a wide range of materials, especially non-Newtonian liquids that require accurate temperature control and small sample volumes. Featuring a coaxial center structure, this viscometer uses small sample adapters, allowing measurements with as little as 15-20 ml of sample. This makes it particularly suitable for expensive or limited samples, while still providing highly reliable and repeatable results.
The device offers a temperature control range from room temperature +10°C to 250°C, with an optional 300°C heating furnace for high-temperature applications. With a display accuracy of two decimal places, this viscometer ensures highly precise readings. The timing measurement function is especially useful for non-Newtonian liquids, where viscosity is not only dependent on temperature and shear rate but also on the length of the measurement time. By ensuring consistent measurement timing, this feature guarantees that the data is both accurate and comparable across tests. Furthermore, the RS232 interface allows for seamless integration with micro printers and computers, making data collection and documentation effortless.
Market Price
The High Temperature Viscometer YG0547 // YG0550 is priced in the range of $3.974 to $5.360 USD, depending on the specific model and configuration selected. This price reflects its advanced features, including temperature control precision, small sample volume requirements, and the ability to test a wide range of materials. For a customized quote, you can request a pricing estimate directly through the Kalstein Plus platform, ensuring you get the best deal based on your specific needs and requirements.
Frequently Asked Questions
- What types of materials can the YG0547 // YG0550 viscometer measure?
This viscometer is designed to test non-Newtonian liquids such as polymers, adhesives, hot melt materials, and asphalt. It is ideal for materials that require heating and melting during viscosity testing. - How precise is the temperature control?
The temperature control accuracy is ±0.1°C, ensuring highly reliable temperature measurements for consistent results. - Can I connect the viscometer to a computer for data management?
Yes, the YG0547 // YG0550 features an RS232 interface, allowing you to connect the device directly to a micro printer or computer for easy data transfer and documentation.
Advantages and Disadvantages
Advantages:
- Small sample size: Only 15-20 ml required, making it efficient and cost-effective.
- Wide temperature range: Room temperature +10°C to 250°C with an optional 300°C furnace for a variety of materials.
- Precise timing function: Ensures consistent viscosity measurements for non-Newtonian liquids.
- Easy integration: RS232 interface allows for seamless connection to external devices like printers and computers for data logging.
- High accuracy: Two decimal precision for all measurements.
Disadvantages:
- Higher initial cost compared to basic viscometers, but justified by the advanced features.
- Requires periodic calibration to maintain measurement accuracy over time.
Product Use in the Field
The High Temperature Viscometer YG0547 // YG0550 is essential in industrial applications such as the production of hot melt adhesives, polymers, and paints, where viscosity plays a key role in the material’s performance and quality. For instance, in the asphalt industry, it helps ensure that the viscosity of the material remains within the optimal range for proper handling and application. The viscometer’s ability to measure viscosity at elevated temperatures makes it ideal for industries that require high precision when testing materials under different conditions.
Recommendations
To get the best results from your High Temperature Viscometer YG0547 // YG0550, we recommend regularly calibrating the device to maintain measurement accuracy. Always ensure the sample adapter is properly cleaned before use to avoid contamination. Additionally, use the timing function to ensure consistency in measurements, especially when testing non-Newtonian liquids. If you’re conducting tests at high temperatures, make sure to monitor the heating furnace to avoid overheating your samples, which could skew results.
Technical Specification
Model | YG0547 | YG0548 | YG0549 | YG0550 |
Display | liquid-crystal display | |||
Speed(r/min) | 0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100 a total of 18 speeds. | |||
Rotor | 18,25,31,34 | 21,27,28,29 (standard configuration) | ||
Measuring range(mPa.s)
|
3- 1.6M 18rotor:3-10K 25rotor:480-1.6M 31rotor:30-100K 34rotor:60-200K |
50 – 2M 21rotor:50-100K 27rotor:250-500K 28rotor:500-1M 29rotor:1K-2M |
100 – 4M 21rotor:100-200K 27rotor:500-1M 28rotor:1K-2M 29rotor:2K-4M |
400 – 16M 21rotor:400-8M 27rotor:2K-4M 28rotor:4K-8M 29rotor:8K-16M |
K = 1,000; M=1,000,000 | ||||
Test error | ±3% (Newtonian liquid) | |||
Repetitive error | ±1.5%(Newtonian liquid) | |||
Temperature control range | Room temperature plus 10℃-250℃ (300℃ optional) | |||
Temperature control accuracy | 0.1℃ | |||
Print interface | YES |