Product Description
The YG1670 Doppler Fetal Monitor is an advanced medical device designed to provide precise and reliable monitoring of fetal health. It features a sophisticated ECG system with capabilities for both 5 lead and 3 lead modes, ensuring comprehensive cardiac assessment. With a high level of accuracy and sensitivity, this monitor measures heart rates in a range of 40 to 240 bpm, making it ideal for detailed fetal heartbeat monitoring.
The YG1670 also includes features for respiratory monitoring via impedance, enhancing its diagnostic capabilities. The NIBP function operates using the oscillometric method, with customizable measuring intervals for efficient blood pressure monitoring. Meanwhile, its SPO2 capabilities allow for precise oxygen saturation and pulse rate monitoring within a 0 to 100% range, displaying results in numeric and waveform formats.
Temperature measurement is another key feature, with a dual-channel system that provides real-time data with an accuracy of 0.1ºC. The device is designed for usability in various medical settings, with an accuracy margin held within ±5% for ECG readings and ±3bpm for heart rate assessments.
| Model | YG1670 | |
| ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) |
| Connection method | I, II, III,AVR,AVL,AVF,V | |
| Lead Mode | 3 Leads (RA,LA,LL) | |
| Connection method | I, II,III | |
| Gain | x250, x500, x1000, x2000 | |
| Accuracy | ±5% | |
| Resolution | 1bpm | |
| Sensitivity | >200(uVp-p) | |
| Differential input impedance | ≥5MΩ | |
| ST segment Monitoring Range | ||
| Measure Range | -1.0~+1.0mV | |
| Measure Accuracy | -0.8mV~+0.8mV | |
| Heart Rate | Measuring range | 40~240bpm |
| Accuracy | ±3bpm | |
| Resolution | 1bpm | |
| Sensitivity | >200UVp-p | |
| Respiration | Method | Impedance between R-F(RA-LL) |
| Measuring Impedance Range | 0.3~3.0 MΩ | |
| Bandwidth | 0.1~2.5Hz | |
| Respiration Rate | Adult: 7~120BrPM | |
| Neo/Ped | 7~150BrPM | |
| Resolution | 1 BrPM | |
| Accuracy | ±2 BrPM | |
| NIBP | Method | Oscillometric |
| Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
| Measuring Period in STAT Mode | 5 Min | |
| Pulse Rate Range | 40~240bpm / 40~150bpm | |
| Alarm Type | SYS, DIA, MEAN | |
| Resolution | ||
| Pressure | 1mmHg | |
| SPO2 | Display | Number of SPO2,waveform of capacity,Pulse |
| Measuring range | 0~100% | |
| Resolution | 1% | |
| Accuracy | 70~99% (±2%) | |
| Pulse rate range | 0~300bpm | |
| TEMP | Channel | 2 |
| Measuring and Alarm Range | 0~50ºC | |
| Resolution | 0.1ºC | |
| Accuracy | 0.1ºC | |
| Actualization interval | about 1 Second. | |
| Average Time Constant | <10 Second. | |
Market Price
The market price of the YG1670 Doppler Fetal Monitor can vary significantly based on distribution channels and additional service offerings like training or extended warranties. On average, this sophisticated medical equipment is priced between $1,500 and $3,000 USD. As with most medical devices, prices can differ based on region and supplier policies, so it is advisable to consult multiple sources to secure the best deal.
Frequently Asked Questions
What is the YG1670 Doppler Fetal Monitor used for?
This device is designed to monitor fetal heart rates, respiratory functions, and other vital parameters during pregnancy, providing essential data to healthcare professionals.
Is the YG1670 suitable for home use?
While technically possible, it is intended for professional healthcare settings where medical oversight ensures accurate reading and interpretation of data.
Does the monitor require regular calibration?
Yes, for optimal accuracy, periodic calibration as recommended by the manufacturer is necessary.
Advantages and Disadvantages
Advantages: The YG1670 offers a comprehensive suite of monitoring capabilities across ECG, SPO2, NIBP, and TEMP, featuring high sensitivity and accuracy. Its versatile design encompasses both adult and neonatal parameters, making it valuable in diverse clinical settings.
Disadvantages: Its complexity might necessitate additional training for effective use and interpretation of data. Additionally, the initial investment cost might be high for small clinics or individual practices.
Field Use of the Product
The YG1670 Doppler Fetal Monitor is primarily used in hospitals, clinics, and specialized healthcare facilities. It supports medical staff by providing continuous and detailed monitoring of fetal health in high-risk pregnancies. The device’s ability to operate in multi-lead and multi-channel modes ensures that healthcare professionals have comprehensive data for making critical decisions.
It is especially useful in labor and delivery suites with its capacity for real-time data analysis, ensuring that any variations in fetal heart rate or distress are promptly addressed, thus enhancing maternal and fetal care outcomes.
Recommendations
To maximize its functionality, ensure that the YG1670 is used in conjunction with regular maintenance and calibration. Proper training for users is recommended to fully exploit its advanced features. Additionally, integrating the device within a hospital’s digital information systems can enhance data recording and retrieval efficiency.
If your facility is considering a new fetal monitoring solution, the YG1670 offers reliable and high-performance capabilities, backed by its engineering and design prowess.
Discover the innovation and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with standards of excellence that meet the most demanding needs. Browse our online store, designed to offer you a quick, easy shopping experience with competitive prices. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.