Product Description
The YG1935-YG1940 Counter Pressure Steam Autoclaves are cutting-edge sterilization devices, perfect for ensuring the highest levels of hygiene and safety in various laboratory and medical environments. This autoclave models offer exceptional performance with a working pressure of 0.22 Mpa and a working temperature of 134°C. The temperature range varies from 105°C to 134°C, allowing for customized sterilization processes that best suit your specific needs.
Each model guarantees precise sterilization control with a temperature accuracy of 0.1°C and a heat average deviation of less than 1°C. They are designed to accommodate varying load sizes, with options ranging from 35L to 75L, and are equipped with robust basket systems for efficient load management. Safety is also a priority with built-in casters and brakes for ease of mobility and placement. With power options of 2.5 KW, 3.0 KW, and 4.5 KW, the YG1935-YG1940 series stands ready to meet diverse operation demands.
| Model | YG1935 | YG1936 | YG1937 |
| Working pressure | 0.22Mpa | ||
| Working temperature | 134°C | ||
| Working temperature range | 105-134°C | ||
| Sterilization time range | 0-99 min or 0-99 hour 59min | ||
| Temperature accuracy | 0.1°C | ||
| Heat average | <1°C | ||
| Air pressure | 0.24Mpa | ||
| Water pressure | 0.15-0.25Mpa | ||
| Voltage | 110-240V. 50/60Hz | ||
| Loading | 2 pcs basket | ||
| Caster | Casters with brake | ||
| Power | 2.5 KW | 3.0 KW | 4.5 KW |
| Size | 35L/0318×450 mm | 50L/0340×550 mm | 75L/0400×600 mm |
| G.W. / N.W. | 72 kg/56 kg | 88 kg/68 kg | 100 kg/80 kg |
Market Price
The pricing for the YG1935-YG1940 Counter Pressure Steam Autoclave range varies based on capacity and power specifications. Typically, smaller models like the YG1935, with a 35L capacity, can be priced in the range of $3,000 to $4,000. The mid-sized YG1936 at 50L usually retails for approximately $4,500 to $6,000. The YG1937, being the largest with a 75L capacity, can be priced around $6,500 to $8,000. Prices may differ based on suppliers, shipping costs, and additional accessories or support services.
Frequently Asked Questions
What maintenance is required for the YG1935-YG1940 autoclaves?
Regular cleaning and inspection of seals and pressure gauges are recommended to maintain optimal performance. Refer to the manual for specific maintenance schedules.
Are these autoclaves suitable for sterilizing all types of equipment?
These models are designed to sterilize a wide range of materials; however, it’s important to consult the manufacturer’s guidelines regarding specific materials or equipment that might be sensitive to heat or moisture.
Is it possible to run these autoclaves at a lower voltage?
The autoclaves are built to operate within a voltage range of 110-240V. Operating outside this range is not recommended and could damage the equipment.
Advantages and Disadvantages
Advantages: The YG1935-YG1940 models offer precise temperature control and high efficiency, essential for critical sterilization tasks. The range of sizes provides flexibility for different load capacities while ensuring full compliance with industry standards. The casters with brakes make the units easily movable and stable during operation.
Disadvantages: The initial investment can be significant, especially for higher-capacity models. Additionally, the autoclaves require a continuous supply of water and reliable power sources, which might be a limitation in certain settings.
Product Usage in the Field
In professional environments such as hospitals, laboratories, and research facilities, the YG1935-YG1940 autoclaves are indispensable. They are routinely used to sterilize surgical instruments, lab equipment, and even non-sensitive materials that require stringent decontamination. With programmable cycles, operators can adjust time and temperature settings to accommodate different sterilization needs.
The ability to operate within a broad temperature range makes these autoclaves versatile enough for various applications, from basic sterilization to more complex processes requiring specific conditions.
Recommendations
To maximize the use of the YG1935-YG1940 Counter Pressure Steam Autoclaves, ensure regular maintenance is carried out as prescribed. It is also beneficial to train staff thoroughly on operational protocols and safety measures. Selecting the appropriate model according to your capacity needs will prevent overloads and ensure optimal performance.
Consider investing in compatible accessories and parts to streamline your sterilization processes further and consult with Yulgary’s customer support for any advanced technical guidance or service requirements.
Discover the innovation and quality that Yulgary has to offer you. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with standards of excellence that meet the most demanding needs. Browse our online store, designed to offer you a quick, easy shopping experience with competitive prices. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.