Product Description
The Infant Incubator YG0426 is a top-tier medical device designed with state-of-the-art features to create a controlled microenvironment crucial for the care of premature and ill newborns. Engineered by Yulgary, this model stands out in the neonatal care industry, providing precise temperature and humidity control to ensure the optimal growth and safety of the most delicate patients.
A key aspect of this incubator is its ability to maintain constant air mode temperatures ranging from 25.0°C to 37.0°C, alongside a skin mode temperature adjustable between 34.0°C and 37.0°C. The device includes an automatic alarm system that alerts caretakers if the air temperature exceeds 38.0°C or the skin temperature goes above 40.0°C, which is crucial for maintaining safe conditions within the incubator.
The meticulous engineering of the YG0426 ensures high temperature accuracy in both air and skin mode, with a precision margin of ±0.5°C and a mattress temperature uniformity of ≤0.8°C, respectively. Furthermore, the incubator supports a humidity control range from 30% to 90% RH, crucial for maintaining the proper humidity levels necessary for newborn health.
| Model | YG0426 |
|---|---|
| Electrical requirement | ~220V 50Hz |
| Heater Power | 550VA |
| Air mode temperature range | 25.0°C-37.0°C |
| Skin mode temperature range | 34.0°C-37.0°C |
| Air mode temperature alarm | <38.0°C |
| Skin mode temperature alarm | < 40.0°C (Air temperature) |
| Air mode high temperature range | 37.1°C~39.0°C |
| Skin mode high temperature range | 37.1°C~38.0°C |
| High temperature mode alarm | < 40.0°C (Air temperature) |
| Air mode temperature display range | 20.0°C-45.0°C |
| Skin mode temperature display range | 25.0°C~45.0°C |
| Air mode alarm | ±3.0°C |
| Skin mode alarm | ±1.0°C |
| Skin temperature sensor accuracy | ±0.3°C |
| Temperature control accuracy | ≤0.5°C |
| Mattress temperature uniformity | ≤0.8°C |
| Humidity control range | 30-90%RH |
| Humidity display range | 0-99.9%RH |
Market Price
The infant incubator market offers a wide range of options, with prices influenced by the level of technology and features included. The YG0426 model, given its advanced specifications and reliable performance, typically falls into the higher end of the price spectrum. Prices can vary, but you might expect a range from $5000 to $7000, reflecting its sophisticated capabilities and durability. This investment is justified by the critical importance of precise and reliable equipment in neonatal care settings.
Frequently Asked Questions
How does the YG0426 ensure temperature accuracy?
The YG0426 is equipped with advanced sensors and control systems that maintain temperature accuracy within a margin of ±0.5°C, ensuring optimal conditions for neonatal care.
What is the power requirement for this incubator?
The electrical requirement for the YG0426 is ~220V 50Hz, with a heater power of 550VA, which is standard for hospital equipment in most regions.
Can the humidity level be adjusted?
Yes, the YG0426 allows for humidity control within a range of 30% to 90% RH, which can be adjusted to meet the specific needs of each patient.
Advantages and Disadvantages
Advantages:
The YG0426 offers several advantages, including precise temperature and humidity control, an intuitive alarm system, and high accuracy in sensor readings. These features are essential for maintaining the health and safety of newborns requiring intensive care.
Disadvantages:
One of the potential disadvantages might be its higher cost compared to less sophisticated models. However, this is offset by its superior features and reliability. Additionally, the specific electrical requirements may not be compatible with every facility without some modifications.
Product Use in the Field
The Infant Incubator YG0426 is predominantly used in neonatal intensive care units (NICUs) where maintaining an optimal environment for newborns is critical. Its precision in temperature and humidity control makes it ideal for premature infants who require specialized care. Nurses and healthcare providers rely on its alarm systems to alert them of any deviations that could affect infant safety.
The robust design and user-friendly interface allow for seamless integration into clinical settings, providing healthcare professionals with the tools needed to deliver exceptional care to the most vulnerable patients.
Recommendations
For optimal use of the YG0426, it is recommended to conduct regular maintenance and calibration of sensors to ensure ongoing accuracy and reliability. Training staff thoroughly on the incubator’s functions and alarm systems will maximize its effectiveness and immediate response to any alerts.
Ensure that the power supply meets the ~220V 50Hz requirement and that the incubator is placed in a stable environment to prevent unnecessary disturbances. Additionally, regularly reviewing and adjusting humidity levels according to each infant’s medical needs can enhance patient outcomes.
Discover the innovation and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with excellence standards that meet the most demanding needs. Browse our online store, designed to provide you with a quick, easy shopping experience at competitive prices. Don’t miss the opportunity to upgrade your laboratory with the best in scientific technology. Click here to explore our catalog.