Product Description
The YG0983 Infusion Suction Pump is at the forefront of medical equipment, offering precision and reliability for various medical settings. This advanced drip type infusion pump uses a peristaltic fingers pumping form to ensure an accurate and consistent infusion rate. With its adjustable fall rate range of 1 to 400 drops per minute, and a volume rate range of 1 to 1200 ml per hour, this device provides healthcare professionals with the flexibility and control required for effective patient care.
Designed for precision, the pump boasts a flow accuracy within approximately 3%, and mechanical precision within 2%, utilizing the manufacturer’s designated IV kit or a high-quality calibrated IV kit. The infusion device supports a purge rate of 800 ml per hour and maintains a Keep Vein Open (KVO) rate of 1 ml per hour, which increases to 3 ml per hour for infusion volumes exceeding 300 ml per hour.
| Model | YG0983 |
| Pump type | Drip Type Infusion Pump |
| Pumping Form | peristaltic fingers |
| Adjustable Fall Rate Range | 1 ~ 400 drops / min (step: 1 drop / min) |
| Adjustable Volume Rate Range | 1 ~ 1200 ml / h (when 1 ~ 99.9 ml / h, step: 0.1 ml / h; greater than 99.9 ml / h, step: 1 ml / h) |
| Flow Accuracy | Within 3% or so (using manufacturer’s designated IV kit or high quality calibrated IV kit) |
| Mechanical precision | within 2% or so |
| Purge Rate | 800 ml / h |
| KVO rate | 1 ml / hour (1 ~ 300 ml / hour); 3 ml / h (more than 300 ml / h) |
| Infusion Volume Range | 1 ml ~ 9999.9 ml (step: 0.1 ml) |
| Maximum Accumulated Volume | 9999.9 ml (step: 0.1 ml) |
| Time interval | 1 min ~ 9999 min (step: 1 min) |
| Occlusion Alarm Threshold | Height: 800 mmHg ± 200 mmHg (106.7 kPa ± 26.7 kPa) Medium: 500 mmHg ± 100 mmHg (66.7 kPa ± 13.3 kPa) Low: 300 mmHg ± 100 mmHg (40.7 kPa ± 13.3 kPa) |
| Alarm | Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle. |
| Air Bubble Detector Method | ultrasonic wave, sensitivity: greater than or equal to 25 l |
| Fuse | F1AL / 250V (“F” indicates fast, “L” indicates low breaking power), 2 pieces (installed inside the pump). |
| Power supply | AC 85 ~ 265V, 50 / 60Hz |
| Internal Battery | 11.1V rechargeable lithium-ion battery. Capacity: greater than or equal to 2000 mAh; the pump can run more than 4 hours at a flow rate of 25ml / h after charging for 8 hours (average flow rate specified by GB 9706.27-2005). |
| Energy | less than or equal to 40VA |
| Size | 188mm (length) x 198mm (width) x 228mm (height) |
| Weight | 2.2 kg |
| Environmental Requirements | Transport: Ambient temperature: -30 ° C ~ + 55 ° C Relative humidity: 20% ~ 95% (non-condensing) Atmospheric pressure: 70kPa ~ 106kPa |
| Storage | Ambient temperature: -30 ° C ~ + 55 ° C Relative humidity: 20% ~ 95% Atmospheric pressure: 70kPa ~ 106kPa |
| Operation | Ambient temperature: + 5 ~ + 40 ° C Relative humidity: 20% ~ 90% Atmospheric pressure: 86kPa ~ 106kPa |
| Calibration Function | disposable IV set of any brand is suitable for this pump |
| Three Working Modes | Rate / volume / time mode |
| Alarm | Infusion Full, Empty, Bad Signal, Malfunction, Occlusion, Door Open, Air Bubble, Low Battery, Setup Error, AC Power Off, Idle. |
Market Price
The YG0983 Infusion Suction Pump falls within a competitive price range that reflects its advanced capabilities and comprehensive features. On the market, devices of this caliber typically range from $1,500 to $2,500, depending on regional variations, supplier pricing, and additional accessories or warranty options. Comparing its specifications and functionality against similar products can help establish its value proposition.
Frequently Asked Questions
What are the main features of the YG0983 Infusion Suction Pump?
The YG0983 features an adjustable infusion rate, high flow accuracy, various alarm systems, and multiple working modes, all designed for precision in medical settings.
How long does the internal battery last?
The pump’s 11.1V rechargeable lithium-ion battery can last over 4 hours at a flow rate of 25 ml/h after a complete 8-hour charge.
What is the occlusion alarm threshold?
The device offers three levels for occlusion alarms: high (800 mmHg ± 200 mmHg), medium (500 mmHg ± 100 mmHg), and low (300 mmHg ± 100 mmHg).
Can the pump use any IV set for calibration?
Yes, the YG0983 is compatible with disposable IV sets of any brand for calibration.
Advantages and Disadvantages
Advantages: The YG0983 offers exceptional precision and versatility with its multiple alarm systems, adjustable infusion settings, and long-lasting battery life. Its compatibility with various IV sets provides further convenience and adaptability in diverse medical environments.
Disadvantages: Despite its advanced features, the initial cost may present a drawback for some small-scale operations or clinics with limited budgets. Additionally, the complexity of options may require thorough training for effective use.
Product Use in the Field
In practical scenarios, the YG0983 Infusion Suction Pump excels in providing consistent and accurate infusion rates critical for effective patient treatment. Its peristaltic technology is particularly suited for applications requiring stringent control over infusion volumes and precise medication delivery. The device’s multi-mode functionality allows healthcare settings to tailor use according to specific medical needs, ensuring patient safety and therapeutic efficacy.
The robust alarm and detection systems ensure that the YG0983 can be trusted in critical situations, alerting staff to any immediate issues such as occlusions or air bubbles. By maintaining a constant infusion flow, medical professionals can focus on patient care without concern for equipment reliability.
Recommendations
To maximize the utility and lifecycle of the YG0983 Infusion Suction Pump, it is recommended to adhere to regular maintenance schedules and thorough training procedures for staff. Familiarity with its varied settings and alarm systems will enhance operability and ensure safe usage. Furthermore, take advantage of its flexible calibration options by using high-quality IV kits tailored to specific medical needs.
For optimal performance, store and operate the device within the recommended environmental conditions. Regular battery charging routines will ensure readiness, particularly in settings prone to emergency power outages. Partnering with reputable suppliers for genuine components and accessories will further ensure long-term serviceability and function.
Discover the innovation and quality that Yulgary has to offer. If you’re looking for high-performance laboratory equipment, you’re in the right place. At Yulgary, we manufacture products with standards of excellence that meet the most demanding needs. Navigate our online store, designed to provide you with a fast, easy shopping experience and competitive prices. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.