Product Description
The YG0316 Ultra-Low Temperature Lab Freezer is designed to meet the demanding needs of scientific laboratories. With a substantial capacity of 338 liters (11.93 cu.ft), it offers ample space to accommodate various samples, making it ideal for storage in research labs and medical facilities. The freezer incorporates a stainless steel interior, complemented by a color-sprayed steel exterior, ensuring durability and ease of cleaning.
This model employs a direct cooling system and operates manually for defrosting, using an HC refrigerant for efficient freezing. Its temperature range stretches from -40°C to -86°C, handled by a reliable microprocessor temperature controller and displayed on a clear LCD screen. Equipped with SECOP compressors, the unit ensures consistent and effective cooling, essential for maintaining the integrity of sensitive samples.
Furthermore, the YG0316 is equipped with sophisticated alarm systems designed to notify users of high or low temperatures, power failures, sensor malfunctions, and more, ensuring heightened security for the stored contents. Additional features include USB ports, optional chart recorders, and data loggers for comprehensive data communication and storage solutions.
For those seeking both practicality and performance, the freezer comes mounted on castors for easy maneuverability and includes multiple internal shelves and storage racks to optimize organization within the unit.
| Model | YG0316 | |
| Specifications | Shelf/drawer QTY | Stainless steel shelf/3 |
| Cooling | Direct cooling | |
| Defrost | Manual | |
| Refrigerant | HC | |
| Power Consumption(kWh/24h) | 12.8 | |
| Noise(db) | 50 | |
| Ambient Temperature(℃) | 10~32℃ | |
| Temperature Range(℃) | -40~-86℃ | |
| Cooling system | Compressor brand/QTY | SECOP/2 |
| Sensor | PTC | |
| Temperature Controller | Microprocessor | |
| Display | LCD display | |
| Power | Voltage/frequency(V/Hz) | 220/50Hz |
| Power(W) | 870W | |
| Current(A) | 6.75A | |
| Material | Inside Material | Stainless steel |
| Outside Material | Color sprayed steel | |
| Insulation | PURF | |
| Size | Capacity(L/cu.ft) | 338/11.93 |
| NT./GT.(kg) | 250/305 | |
| Exterior size(W*D*H)(mm) | 880*980*1940 | |
| Interior size(W*D*H)(mm) | 488*607*1140 | |
| Package size(W*D*H)(mm) | 940*1070*2130 | |
| CBM | 2.14 | |
| 20GP/40GP/40HQ | 12/24/24 | |
| Frozen Racks | Racks | 12(4X4) |
| Boxes (2 Inches) | 192 | |
| Samples(2ml) | 19200 | |
| Alarm | High/low temperature | Y |
| Power failure | Y | |
| Abnormal voltage | Y | |
| Sensor error | Y | |
| Filter screen check | Y | |
| Thermostat failure | Y | |
| Low battery | Y | |
| Condenser clean | Y | |
| High ambient temperature | Y | |
| Door Ajar | Y | |
| Power failure backup system(alarm) | ||
| Accessories | Castor | Y |
| Inside door | 2 | |
| Test hole QTY/diameter | 2/25MM | |
| USB port | Y | |
| Chart recorder | Optional | |
| Data logger | Optional | |
| Remote alarm port | Y | |
Market Price
The price of ultra-low temperature lab freezers like the YG0316 varies based on specific features, manufacturer, and place of purchase. On average, these units can range from $5,000 to $12,000 USD. The YG0316, given its advanced specifications and capability, tends to fall on the upper end of this spectrum, reflecting its quality and reliability.
While prices may fluctuate depending on markets and seller policies, it is essential to consider the added value that features like efficient cooling systems and comprehensive alarm notifications bring, which justify the initial investment over time by ensuring the protection of invaluable samples.
Frequently Asked Questions
What is the temperature range of the YG0316?
The YG0316 offers a wide temperature range from -40°C to -86°C, suitable for various storage needs in laboratory settings.
Does this freezer come with a defrost function?
Yes, the YG0316 includes a manual defrost function, which is common in ultra-low temperature freezers to maintain the integrity and lifespan of the unit.
What type of refrigerant is used in this model?
The YG0316 utilizes HC refrigerant, which is known for its high efficiency and low environmental impact.
Are there any data logging options available?
The freezer has optional data logging capabilities through an optional logger or chart recorder, allowing users to track temperature changes over time efficiently.
Advantages and Disadvantages
Advantages:
- High Capacity: With a significant storage capacity of 338 liters, more samples can be stored, organized using the available shelving and racks.
- Efficient Alarm System: Comprehensive alarms cover issues like temperature deviations, power failures, and door ajar for added security.
- Durability: The use of stainless steel and color sprayed steel adds to the unit’s robustness and longevity.
- Low Noise Levels: Operating noise at 50 dB ensures the unit does not contribute significantly to ambient noise in the lab environment.
- Maneuverability: Castors enable easy moving of the unit when necessary.
Disadvantages:
- Manual Defrost: Requires regular manual defrosting, which could be seen as inconvenient in some settings.
- Higher Price Point: The advanced features and capabilities come at a premium cost, which might not be feasible for all budgets.
- Space Requirements: The relatively large dimensions require appropriate room space for installation and operation.
Product Use in the Field
The YG0316 Ultra-Low Temperature Lab Freezer is primarily used in research and medical laboratories where precise and consistent ultra-low temperatures are critical. Its robust design and comprehensive temperature range make it suitable for storing sensitive biological samples, vaccines, enzymes, and other temperature-sensitive materials.
In a practical setting, the freezer is pivotal in preserving sample integrity, facilitating long-term research projects by preventing biological degradation. It also plays a critical role in clinical applications where temperature regulation is essential to maintaining sample efficacy. The advanced alarm systems ensure that any temperature fluctuations or power issues are promptly addressed, safeguarding valuable research materials.
Recommendations
To maximize the utility and longevity of the YG0316 freezer, users should adhere to regular maintenance schedules, including manual defrosting and timely cleaning of the condenser as recommended in its specifications. Ensuring the unit is placed in an environment within its specified ambient temperature range of 10-32°C will optimize its performance.
It’s advisable for laboratories to invest in the optional data logging features, allowing detailed record-keeping of temperature conditions over time, which can be crucial for research documentation and compliance purposes. Furthermore, positioning the freezer on a level surface will help maintain its efficiency and extend its service life.
Understand the innovations and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with standards of excellence that meet even the most demanding needs. Browse our online store, designed to offer you a fast, easy, and competitively priced shopping experience. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.