Product Description
The YG1688 Veterinary Automatic Hematology Analyzer stands out as a cutting-edge device in the field of veterinary diagnostics. Designed to provide highly accurate and efficient blood analysis, this model supports CBC+DIFF and CBC testing modes, ensuring comprehensive results. One of its key technical specifications is its capability to process up to 60 samples per hour, making it ideal for high-demand environments.
With a minimum sample volume requirement of ≤20μL, the YG1688 is both efficient and economical, facilitating blood analysis even with minimal sample quantities. It boasts advanced features such as automatic and manual calibration, which ensure precision and reliability in every use. The analyzer’s QC mode includes L-J and X-B, ensuring quality control that meets the highest laboratory standards.
The device is equipped with four scatter diagrams and three histograms, providing detailed visual data analysis for a better understanding of blood parameters. It also comes with an impressive storage capacity that can hold up to 50,000 sample results, including scatter diagrams and histograms. Weighing 26.5 kg and with dimensions of 364 mm x 498 mm x 431 mm, the YG1688 is compact yet robust, suitable for diverse laboratory settings.
| Model | YG1688 |
| Category | Hematology Analyzer |
| Gross weight (kg) | 1 |
| Scatter diagrams | 4 |
| Histograms | 3 |
| Performance | 60 samples per hour |
| Sample volume | ≤20μL |
| Testing mode | CBC+DIFF, CBC |
| Calibration | Automatic calibration, manual calibration |
| QC mode | L-J, X-B |
| Storage | 50,000 sample results including scatter diagrams and histograms |
| Weight | 26.5kg |
| Dimension | 364mm*498mm*431mm |
| Work environment | Temperature: 10-30℃, Humidity≤70% |
Market Price
The YG1688 Veterinary Automatic Hematology Analyzer is competitively priced within the market for advanced diagnostic equipment. Prices for such analyzers can range depending on features, brand reputation, and additional services such as warranty and customer support. Typically, you might find a price range between $5,000 to $15,000, depending on the specific configurations and supplier offers. For the exact pricing of the YG1688, it’s advised to contact Yulgary directly or authorized distributors.
Frequently Asked Questions
What is the sample volume requirement for the YG1688?
The YG1688 requires a sample volume of ≤20μL, making it efficient and economical for various testing needs.
How many samples can the YG1688 process per hour?
The analyzer is capable of processing 60 samples per hour, which is suitable for high-throughput laboratory settings.
What are the calibration options available with this device?
The YG1688 offers both automatic and manual calibration options to ensure optimal accuracy and performance.
Advantages and Disadvantages
The YG1688 analyzer offers numerous advantages, including high processing speed and efficient sample usage. The inclusion of automatic and manual calibration options provides flexibility and accuracy, ensuring reliable results. Its storage capacity for up to 50,000 sample results is ideal for record-keeping and longitudinal studies.
However, there could be some potential disadvantages. While it is compact, the weight of 26.5 kg might require a stable setup area within the laboratory. Additionally, operational limits within a temperature range of 10-30℃ and humidity levels ≤70% might not be ideal for all geographical locations without climate control.
Product Usage in the Field
The YG1688 is instrumental in veterinary clinics and laboratories, providing precise and rapid blood analysis essential for diagnosing various conditions in animals. Veterinary professionals rely on its efficiency, especially in time-critical situations such as surgical procedures or emergency diagnoses. The analyzer’s detailed scatter diagrams and histograms provide in-depth insights into blood cell health, crucial for developing accurate treatment plans.
Its streamlined sample processing capabilities allow for minimal handling, reducing the potential for errors and contamination. Whether in routine check-ups or research-intensive environments, the YG1688 provides consistent, high-quality performance, making it a valuable asset in veterinary practices.
Recommendations
To maximize the performance of the YG1688 analyzer, it is essential to maintain the device in an environment within specified temperature and humidity ranges. Regularly calibrating the device using both automatic and manual settings can ensure consistent accuracy. It is also recommended to routinely clean and service the analyzer to prolong its longevity and prevent technical issues.
Training laboratory staff on the optimal use and maintenance protocols of the YG1688 can significantly enhance operational efficiency. Additionally, integrating data storage capabilities with laboratory information systems can facilitate easier management and retrieval of patient data, improving overall productivity.
Discover the innovation and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with standards of excellence that meet the most demanding needs. Browse our online store, designed to offer you a quick, easy shopping experience at competitive prices. Do not miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.

