Product Description
The Water Purification System YG1037 by Yulgary is designed to provide high-quality purification with a focus on advanced features suitable for laboratory environments. This system is adapted to use urban tap water as its inlet source, necessitating a water pressure between 0.15-0.5 MPa and operational temperatures ranging from 5-40°C. The streamlined water flow speed operates effectively at 1.5-2L/min.
The various models, including YG1037-1, YG1037-2, and YG1037-3, come with different machine capacities, with outputs of up to 30 L/H. This system ensures that RO water achieves a desalination rate between 95-99% when employing a new RO membrane. Furthermore, it provides UP water with a resistivity of 18.25MΩ.cm@25°C, which exceeds traditional laboratory water standards, ensuring minimal contaminants such as TOC (<3 ppb), particles (>0.22 um, <1/ml), and microorganisms (<1 cfu/ml).
| Model | YG1037 | YG1037-1 | YG1037-2 | YG1037-3 |
|---|---|---|---|---|
| Ribonuclease (RNases) | N/A | N/A | <1pg/ml | <1pg/ml |
| Pyrogen (endotoxin) | N/A | N/A | <0.001 Eu/ml | <0.001 Eu/ml |
| Inlet water source | Urban tap water, inlet water pressure: 0.15-0.5MPa, water temperature 5-40°C | |||
| Water flow speed | 1.5-2L/min (with pressure barrel) | |||
| Machine capacity | 15 L/H | 30 L/H | 15 L/H | 30 L/H |
| Output Water quality | RO water: desalination rate as high as 95-99% (when using new RO membrane) | |||
| UP water quality | UP water: resistivity 18.25MΩ.cm@25°C (higher than laboratory water standard) TOC:<3 ppb, particles (>0.22 um) <1/ml, microorganisms <1 cfu/ml | |||
Market Price
The Yulgary Water Purification System models are competitively priced in the market. Generally, water purification units with similar capabilities range from $1,000 to $3,000, depending on features and specifications. Yulgary’s units, with their advanced technical capabilities, tend to be at the upper end of this range, reflecting their enhanced performance and durability.
While prices can vary based on geographic and vendor differences, investing in the YG1037 series promises a reliable and cost-effective solution for laboratories seeking top-tier water purification systems. Potential buyers can explore further details and pricing options through authorized distributors or directly from Yulgary’s official website.
Frequently Asked Questions
What water sources can the YG1037 series purify?
The YG1037 series is designed to process urban tap water with specified pressure and temperature ranges to ensure optimal purification.
What is the maintenance requirement for the YG1037?
The system requires regular maintenance such as replacing filters and RO membranes as needed to maintain its high purification standards.
How does this system ensure high water quality?
It operates with advanced RO and UP technologies to achieve outstanding desalination rates and purity, exceeding standard laboratory water specifications.
Advantages and Disadvantages
Advantages: The YG1037 series offers superior water purification capabilities, achieving high desalination rates and ultrapure water quality standards. It supports sustainable use by utilizing regular tap water and operating efficiently with a substantial flow rate, making it suitable for busy laboratory settings.
Disadvantages: Although highly efficient, the system can represent a significant upfront investment. Additionally, ongoing maintenance and the need for replacement parts can add to operational costs over time.
Usage in the Field
The YG1037 and its variants are ideal for laboratory environments that demand consistent water purity. Practical usage involves connecting the system to an urban tap supply, allowing it to process and deliver laboratory-grade water reliably. It’s utilized in scenarios like chemical analysis, medical research, and molecular biology where water quality is critical.
In field applications, its reliable performance ensures that users can trust in consistently receiving purified water that meets or exceeds laboratory standards. Therefore, it serves as a backbone for various scientific investigations and experimental applications.
Recommendations
For optimal performance of the YG1037 water purification system, it is recommended to regularly monitor water pressure and temperature within the specified limits. Conduct timely maintenance checks to replace components such as RO membranes and filters, which helps in maintaining maximum efficiency.
It’s also advisable for users to document their purification requirements and schedules, streamlining user experience and enhancing system longevity. Establish a maintenance protocol that includes regular inspections and upgradation to newer models when necessary for sustained performance in dynamic laboratory environments.
Discover the innovation and quality that Yulgary has to offer. If you’re looking for high-performance laboratory equipment, you’ve come to the right place. At Yulgary, we manufacture products with standards of excellence that meet the most demanding needs. Browse our online store, designed to offer you a fast, easy shopping experience with competitive prices. Don’t miss the opportunity to upgrade your laboratory with the best in scientific technology. Click here to explore our catalog.