Help Desk

(+47) 41376523

Articulos

Innovative Vertical Electrophoresis Tank: YG1582 Model

Product Description

The Vertical Electrophoresis Tank, model YG1582, is an advanced tool designed for precise laboratory applications. This equipment is ideal for separating DNA, RNA, or proteins under an electric field. With a gel size of 120×145 mm, and the ability to accommodate gel thicknesses of 1 and 1.5 mm, this tank offers flexibility for various experimental requirements. It includes a 16 to 23 comb wells capacity and a gel capacity of 2, ensuring optimal performance in separation tasks.

The buffer requirement for the YG1582 is 1200 ml, providing efficient operations with minimal resource waste. Its design is crafted to deliver consistent and reliable results, making it an indispensable asset for laboratories dealing in molecular biology and biochemistry. Every aspect of the YG1582 vertical electrophoresis system is engineered to support high-quality outcomes, ensuring that your laboratory’s diagnostic and research needs are met with superior precision and accuracy.

Model YG1582
Gel Size (W×L) mm 120×145
Gel thickness 1, 1.5 (mm)
Comb wells 16, 23
Gel capacity 2
Buffer requirement 1200 (ml)

Market Price

The pricing for vertical electrophoresis tanks like the YG1582 varies depending on the features and the specifications offered by different manufacturers. Generally, prices range from $500 to $2000, reflecting factors such as the material quality, durability, technology, and brand reputation. The YG1582, with its high-performance capabilities, is competitively priced within this spectrum, offering an excellent balance between quality and cost-effectiveness. Hence, it becomes a highly attractive option for laboratories seeking robust performance without compromising on budgetary constraints.

Frequently Asked Questions

What is the YG1582 Vertical Electrophoresis Tank used for?

The YG1582 is used for the separation and analysis of macromolecules such as DNA, RNA, and proteins through electrophoresis. It is vital in genetics research, molecular biology, and biochemistry.

How many gels can the YG1582 accommodate?

The tank accommodates up to 2 gels at a time, allowing for efficient simultaneous analysis.

What is the required buffer for this model?

The YG1582 requires 1200 ml of buffer to operate efficiently, ensuring proper current flow and gel performance during electrophoresis.

Advantages and Disadvantages

Advantages: The YG1582 is designed for efficiency and precision, making it a crucial tool in any molecular laboratory. It offers consistent performance, user-friendly operation, and is constructed with durable materials that promise long-lasting use. Additionally, the flexibility in gel capacity and comb options empowers researchers with the versatility needed for a broad range of applications.

Disadvantages: The primary limitations are the upfront cost for smaller labs and the requirement for maintenance to ensure electrode preservation and system functionality. However, these are common across all electrophoresis systems and can be managed with proper care and planning.

Field Use of the Product

The YG1582 Electrophoresis Tank is employed in various laboratory settings to facilitate critical tasks such as genetic sequencing, protein profiling, and nucleic acid separation. In practical terms, the equipment is set up with samples loaded into the wells, and once a buffer is added, an electric current is applied. The process results in samples migrating across the gel based on size and charge, allowing for subsequent analysis and interpretation.

In settings such as clinical and research laboratories, the YG1582 aids in diagnosing genetic disorders, conducting research in evolutionary biology, and facilitating quality control in pharmaceuticals. Its reliability and precision make it an indispensable tool for research-led environments seeking accurate results and breakthroughs.

Recommendations

To maintain optimal performance, it is recommended to carefully clean the tank and components after each use. Regularly inspect the electrodes for signs of wear and replace them as necessary. Avoid using excessive voltage as it can degrade the gel and reduce the efficacy over time. Always follow the manufacturer’s guidelines for buffer preparation and usage to ensure consistent results.

When storing the equipment, keep it in a dry and temperature-controlled environment to prevent moisture-induced damage or component degradation. Users should also engage in periodic training and updates on electrophoresis techniques to maximize the YG1582’s utility.

Discover the innovation and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with excellence standards that meet the most demanding needs. Browse our online store, designed to offer you a fast, easy shopping experience with competitive prices. Do not miss the opportunity to improve your laboratory with the best in scientific technology. Click here to explore our catalog.