Product Description
The Tabletop Autoclave Class N series, models YG1297 through YG1300, represent cutting-edge sterilization technology essential for laboratories and clinical settings. Offering varying chamber volumes from 8L to 23L, these autoclaves cater to a wide array of sterilization needs, accommodating different load sizes efficiently.
Each model is equipped with a chamber designed to fit specific dimensions, starting from Ø170×320 mm for the YG1297 model up to Ø247×450 mm for the YG1300. The number of trays included also varies, with each model supporting up to a maximum of four trays, allowing optimal space utilization. With a consistent voltage/frequency of 220/110V and 50/60 Hz, and power capacities differing slightly between models—1900W to 2100W—these units deliver high performance. Their overall dimensions, treatment programs, weight, and technical specifications make them adaptable to diverse operational environments.
| Order Code | YG1297 | YG1298 | YG1299 | YG1300 |
|---|---|---|---|---|
| Chamber Dimension (mm) | Ø170×320 | Ø200×360 | Ø247×350 | Ø247×450 |
| Chamber Volume | 8L | 12L | 18L | 23L |
| Number of Trays | 2/ max. 3 | 2/ max. 3 | 3/ max. 4 | 3/ max. 4 |
| Tray Size (mm) | 130×265 | 156×295 | 192×285 | 192×380 |
| Voltage/Frequency | 220/110 V, 50/60 Hz | 220/110 V, 50/60 Hz | 220/110V, 50/60Hz | 220/110V, 50/60Hz |
| Power | 1900W | 1900W | 1900W | 2100W |
| Overall Dimensions (W x H x D) | 420x370x525mm | 420x370x595mm | 490x455x600mm | 490x455x690mm |
| Weight | 35 kg | 38 kg | 45 kg | 50 kg |
| Program | Temperature [°C] | Pressure [Mpa] | Sterilization Time [min.] | |
| Solid | 134 | 210 | 4 | |
| 121 | 110 | 20 | ||
| Liquid | 134 | 210 | 10 | |
| 121 | 110 | 30 | ||
| Wrapped | 134 | 210 | 10 | |
| 121 | 110 | 30 | ||
| Textile | 134 | 210 | 10 | |
| 121 | 110 | 30 | ||
| Prion | 134 | 210 | 18 | |
| Drying | – | – | – |
Market Price
In the current market, Tabletop Autoclaves of the Class N series range significantly in price, reflecting their advanced features and capacity. Typically, prices can start at approximately $1500 for the lower capacity models and can go up to $3500 or higher for those offering larger chambers and enhanced functionalities. These competitive prices highlight their value in providing reliable sterilization solutions across various laboratory or medical settings.
Frequently Asked Questions
What is the power requirement for these autoclaves?
The Tabletop Autoclave Class N series requires a power input of 220/110V, operating at both 50 and 60 Hz frequencies. The power consumption ranges from 1900W for the smaller models to 2100W for the larger ones.
How does the sterilization process work?
These autoclaves utilize high-pressure saturated steam to sterilize instruments, ensuring all microorganisms are effectively eradicated. The process involves several cycles to manage different materials like solids, liquids, wrapped, and textile items.
Can these autoclaves handle delicate equipment?
Yes, with programmable settings for temperature and pressure, these autoclaves can accommodate delicate instruments with precision, thereby offering versatile sterilization procedures.
Advantages and Disadvantages
Advantages: The Tabletop Autoclaves boast compact designs, suitable even for limited spaces, while ensuring high efficiency with state-of-the-art sterilization processes. Their variety in chamber sizes and capacities makes them adaptable for multiple applications.
Disadvantages: Despite being efficient, the initial investment in these high-quality autoclaves can be significant, which may be a consideration for smaller laboratories or facilities with limited budgets.
Product Usage in the Field
The utilization of the Tabletop Autoclave Class N models spans across various fields such as dental clinics, veterinary practices, and laboratory environments. Their ability to sterilize different load types, from wrapped materials to liquids, ensures they are indispensable in maintaining sterile equipment and instruments.
These autoclaves are also critical in educational institutions where laboratory experiments require the use of sterile tools to prevent contamination. Because of their advanced features, operators can seamlessly integrate them into workflows without extensive training.
Recommendations
To maximize the efficiency and longevity of your Tabletop Autoclave Class N, regular maintenance is recommended. Ensure that all components are checked routinely for wear and tear, and replace parts as needed. Additionally, operators should adhere to the specified load capacities to prevent overloading, which can compromise sterilization efficacy.
For optimal results, use only distilled or deionized water during sterilization processes to avoid mineral deposits that can affect performance over time. Comprehensive reading of the user manual and training for operators can also be beneficial in achieving the best outcomes from these devices.
Discover the innovation and quality that Yulgary has to offer. If you’re looking for high-performance laboratory equipment, you’re in the right place. At Yulgary, we manufacture products with standards of excellence that meet the most demanding needs. Browse our online store, designed to offer you a quick, easy shopping experience with competitive prices. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.