Product Description
The Horizontal Cylindrical Pressure Steam Autoclave, available in models YG1289 to YG1293, stands out as a top-tier sterilization device in laboratories and medical facilities. These autoclaves feature a consistent working pressure of 0.22Mpa and a working temperature of 134℃, ensuring effective sterilization of instruments and materials. The temperature can range between 105-134℃, which allows flexibility in handling different materials sensitive to heat.
These models boast a sterilization time ranging from 0 to 60 minutes, complemented by a drying time within the same range. This versatility ensures that instruments are not only sterilized but also dry and ready for immediate use. The autoclaves are designed with precision, maintaining an average heat deviation of ≤±1℃.
For varying facility needs, the chamber size varies across models: 150L to 500L, with corresponding outer and packing sizes ensuring easy accommodation and transport. The energy consumption ranges from 9kw to 18kw, depending on the size, making these autoclaves efficient yet powerful tools in any laboratory or medical setting.
| Model | YG1289 | YG1290 | YG1291 | YG1292 | YG1293 |
| Work pressure | 0.22Mpa | ||||
| Work temperature | 134℃ | ||||
| Working temperature range | 105-134℃ | ||||
| Sterilization time | 0 – 60 minutes | ||||
| Drying time | 0 – 60 minutes | ||||
| Average heat | ≤±1℃ | ||||
| Chamber size (mm) | 150L / Ø440×1000 | 200L / Ø500×1000 | 300L / Ø600×1080 | 400L / Ø700×1100 | 500L / Ø700×1300 |
| Outer size (mm) | 1400×600×1300 | 1400×670×1650 | 1400×770×1780 | 1430×880×1830 | 1800×900×1820 |
| Packing size (mm) | 1550×750×1850 | 1560×820×1850 | 1680×920×2100 | 1600×1050×2100 | 1850×1050×2100 |
| GW / NW | 320/240kg | 350/260kg | 465/365kg | 530/420kg | 580/470kg |
| Energy | 9kw | 9kw | 12kw | 18kw | 18kw |
Market Price
The horizontal cylindrical pressure steam autoclave falls into a premium price range due to its advanced features and reliable performance. Typically, these models can range from $5,000 to $15,000, depending on the specific model and size you choose. Factors such as warranty, additional features, and the purchase source can also influence the final pricing. It’s recommended to explore various suppliers and consider bundled offers for enhanced value.
Frequently Asked Questions
What is the maximum temperature these autoclaves can reach?
The maximum working temperature for these models is 134℃, which is optimal for ensuring thorough sterilization of medical instruments.
How much energy do these autoclaves consume?
Energy consumption varies by model, ranging from 9kw for smaller models to 18kw for larger models. This ensures efficiency without compromising performance.
Are these autoclaves suitable for all types of materials?
Yes, these autoclaves can handle a wide variety of materials, but it is crucial to ensure the material can withstand the autoclave’s temperature and pressure.
Advantages and Disadvantages
Advantages:
- Consistent temperature and pressure for reliable sterilization.
- Varying chamber sizes which cater to different needs.
- Energy-efficient models, suitable for continuous use.
- Sturdy construction ensures durability and long service life.
Disadvantages:
- Higher upfront cost compared to basic sterilization equipment.
- Requires regular maintenance to ensure peak performance.
Product Use in the Field
In practical scenarios, the horizontal cylindrical pressure steam autoclave is widely used in both medical and laboratory environments. It’s ideal for sterilizing surgical instruments, laboratory tools, and other high-risk materials. Given its capacity and versatility, the autoclave can handle everything from small batches of tools to larger loads, making it indispensable in high-traffic facilities.
Operators can count on its user-friendly controls to manage sterilization cycles, and the drying function ensures that instruments are ready for use immediately after the cycle ends. This time-saving feature is particularly beneficial in settings where rapid turnaround is essential.
Recommendations
To maximize the use and longevity of your autoclave, consider the following recommendations:
- Regularly schedule maintenance checks to ensure all components function correctly.
- Train all users thoroughly on operating procedures and safety protocols.
- Use only recommended cleaning agents to avoid damaging the equipment.
- Invest in a quality water source to prevent mineral buildup within the system.
Discover the innovation and quality that Yulgary has to offer. If you’re looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products to the highest standards of excellence meeting the most demanding needs. Browse through our online store, designed to offer you a fast, easy shopping experience with competitive prices. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.