Product Description
The Yulgary Recirculating Chiller models YG1269, YG1270, YG1271, and YG1272 are expertly designed for diverse laboratory applications requiring precise temperature control. Each model operates within a broad working temperature range of -30 to 5°C, allowing them to meet the demands of various scientific experiments and processes. The temperature stability is maintained at ±2°C, ensuring reliable and consistent performance.
These chillers are equipped with different rated powers ranging from 1070 to 1475 watts, adaptable to a standard power supply of 220-240V~, 50/60Hz, although model YG1272 requires a 3~, 380V, 50Hz supply. Cooling capacities differ across models, accommodating specific operational needs from 0°C to -25°C.
The refrigerant used in models YG1269, YG1270, and YG1271 is R410A, while model YG1272 employs R404A for enhanced efficiency. The bath fluid capacity ranges from 10 to 40 liters, making these chillers ideal for a variety of applications. Furthermore, the circulating pump flow rate is measured at 20L/min for the first three models and 30L/min for the YG1272, with pressure capabilities of 0.4 bar and up to 1 bar for YG1272.
| Model | YG1269 | YG1270 | YG1271 | YG1272 | |
| Working Temperature Range | -30 ~ 5°C | ||||
| Temperature Stability | ± 2°C | ± 2°C | |||
| Power Supply | 220-240V~, 50/60Hz | 3~, 380V, 50Hz | |||
| Rated power | 1070 | 1475 | 1275 | 1475 | |
| Cooling Capacity | 0°C | 1250 | 1750 | 2800 | 6000 |
| -10°C | 800 | 1100 | 1800 | 4000 | |
| -20°C | 300 | 700 | 1000 | 2500 | |
| -25°C | 150 | 300 | 500 | 7100 | |
| Refrigerant | R410A | R404A | |||
| Bath Fluid Filling Volume (L) | 10 | 17 | 30 | 40 | |
| Circulating Pump Flow Rate | 20L/min | 30L/min | |||
| Pressure (bar) | 0.4 | 1 | |||
| Hose Connection Size | 1 / 2″ | 3 / 4″ | |||
| Dimensions (mm) | 435W x 690D x 720H | 465W x 690D x 820H | 495W x 760D x 860H | 650W x 1050D x 1070H | |
| Net Weight (kg) | 70 | 80 | 100 | 195 | |
Market Price
The price for recirculating chillers can vary based on their technical capabilities and specific model features. Typically, the market range for these chillers lies between $1,500 and $5,000. The initial cost may seem significant; however, the long-term efficiency and precise temperature control these units provide make them a valuable investment for laboratories that require stringent temperature management.
Frequently Asked Questions
What is the main application of these chillers?
The primary use of these chillers is to maintain precise temperature control in laboratory experiments and processes.
Are the chillers energy efficient?
Yes, the chillers are designed to optimize energy use with high cooling capacities, delivering efficient performance.
What type of refrigerant is used in these models?
Models YG1269, YG1270, and YG1271 use R410A, while model YG1272 uses R404A.
Advantages and Disadvantages
Advantages: The YG series chillers provide excellent temperature control, energy efficiency, and adaptability for diverse applications with varying operational needs. Their robust design ensures long-term durability and reliability.
Disadvantages: The initial investment can be significant, and some models require a specific power supply setup, such as the YG1272 which needs a 3~, 380V, 50Hz supply.
Product Use in the Field
In practical settings, these chillers are used in laboratories where precise cooling is crucial. They are often employed in chemical, pharmaceutical, and life sciences applications where temperature-sensitive processes are routine. The user benefits from consistent temperature stability, ensuring accurate experimental outcomes and process reliability.
The modular design and varied pump flow rates make these chillers versatile, as they can be integrated into various laboratory setups with ease. Their ability to maintain stable low temperatures enables sensitive processes such as crystallization and distillation to be performed efficiently.
Recommendations
To maximize the benefits of these chillers, ensure regular maintenance checks to verify the integrity of hoses and electrical components. Consider investing in surge protectors to safeguard against power fluctuations, particularly for models requiring specific power supplies like the YG1272.
It’s also recommended to pair the chillers with compatible laboratory equipment to fully exploit their temperature control capacities. For optimal performance, familiarize yourself with the user manual to understand operation details and maintenance requirements.
Discover the innovation and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with excellence standards that meet the most demanding needs. Browse through our online store, designed to offer you a fast, easy shopping experience with competitive prices. Don’t miss the opportunity to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.