The Biological Safety Cabinets YG0176-1 and YG0177-1 by Yulgary are state-of-the-art essential tools for laboratories focused on maintaining a pathogen-free environment. Engineered to meet the International Standard ISO14644.1 CLASS 5, these cabinets offer a protective barrier between the user and samples, thereby ensuring optimal levels of safety during sensitive operations.
Both models boast an inflow velocity of 0.53m/s and a downflow velocity of 0.35m/s with a precision of ±0.015m/s, which ensures a steady and controlled airflow essential for maintaining cleanliness and accuracy in experimental processes. The noise level is minimized to ≤65 dB, allowing for a quieter work environment, while low vibration at ≤3μm (X, Y, Z direction) enhances the stability of delicate tasks.
The filtration system is a standout feature, equipped with HEPA filters boasting an efficiency of 99.995%, ensuring that airborne contaminants are almost completely removed from the air stream. With a light intensity of ≥650 LX, the workspace is well-illuminated, supporting detailed tasks and improving user comfort and productivity.
| Model | YG0176-1 | YG0177-1 |
| Clean Rating | International Standard ISO14644.1 CLASS 5(US209E,CLASS 100) | |
| Inflow Velocity | 0.53m/s | |
| Down Flow Velocity | 0.35m/s | |
| Down Flow Velocity Precision | ±0.015m/s | |
| Noise Level (dB) | ≤65 | |
| Vibration | ≤3μm (X, Y, Z direction) | |
| HEPA | Efficiency 99.995% | |
| Light Intensity (LX) | ≥650 | |
| Pressure Difference Range (Pa) | 0~500 | |
| Operate Environment | Environment temperature: 10-30℃, relative humidity under 70%, no obvious vibration and dust | |
| External Dimensions (H*W*D) (mm) | 2120×1035×740 | 2120×1340×740 |
| Dimension of Working Zone (H*W*D) (mm) | 670×965×560 | 670×1260×560 |
| Power (W) | 300 | 350 |
| Net Weight (KG) | 175 | 210 |
| Gross Weight (KG) | 195 | 235 |
| Package Size (H*W*D) (mm) | 1710×1205×910 | 1710×1510×910 |
Market Price
The pricing for the Yulgary Biological Safety Cabinets YG0176-1 and YG0177-1 varies depending on location and distributor. On average, prices range between $3,000 and $6,000, contingent on features such as HEPA filter replacement frequency, warranty period, and additional services like installation and training. This investment ensures a safe working environment and reliable product lifetime.
Frequently Asked Questions
What is the clean rating of these biological safety cabinets?
The YG0176-1 and YG0177-1 models meet the International Standard ISO14644.1 CLASS 5 (US209E, CLASS 100), ensuring high cleanliness and contamination control.
What type of filtration system is used?
Both models are equipped with HEPA filters that achieve 99.995% efficiency, providing superior air cleanliness and safety.
Is it suitable for use in environments with high humidity?
These cabinets are best operated in environments with a relative humidity of under 70% to maintain efficiency and extend equipment lifespan.
Advantages and Disadvantages
Advantages: The Yulgary Biological Safety Cabinets offer a robust filtration system that meets the highest international standards of air purity. With their low noise and vibration levels, they create optimal working conditions for laboratory personnel. Additionally, the light intensity ensures that users can work efficiently with minimal eye strain.
Disadvantages: The primary drawback is the limitation in operating environments, as conditions of high humidity or excessive dust can affect functionality. Additionally, the purchase and maintenance costs might be a consideration for smaller laboratories or institutions with limited budgets.
Field Use
In a practical setting, Yulgary’s Biological Safety Cabinets are invaluable in microbiology labs, pharmaceutical environments, and research institutions. They serve as the frontline defense in maintaining a sterile work environment, essential for handling biohazardous materials and samples.
The user places the samples and conducts laboratory work within the designated work zone, protected by the cabinet’s consistent airflow filtration, which prevents escape of potentially dangerous microbes. The clear viewing glass and interior lighting aid precision and accuracy in experiments.
Recommendations
To maximize the utility and lifespan of your Yulgary Biological Safety Cabinet, regular maintenance, including HEPA filter replacements and consistent calibration checks, are essential. Position the cabinet in a vibration-free area with a controlled temperature, maintaining environmental norms recommended by the manufacturer.
Ensure that lab personnel are trained in the correct operation practices of the cabinets, which can prolong the equipment’s durability and maintain its performance. Regular inspections by technicians can also pre-emptively identify potential issues, ensuring continued compliance with safety standards.
Discover the innovation and quality that Yulgary has to offer. If you are looking for high-performance laboratory equipment, you are in the right place. At Yulgary, we manufacture products with excellence standards that meet the most demanding needs. Browse our online store, designed to offer you a fast, easy shopping experience with competitive prices. Don’t miss the chance to enhance your laboratory with the best in scientific technology. Click here to explore our catalog.